Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,505

The DOI matches its Crossref record.

Evaluation of single-crystal X-ray diffraction data from a position-sensitive detector

Kabsch, W.·1988·Journal of Applied Crystallography

Abstract

A Fortran program has been developed for the reduction of single-crystal diffraction data from a sequence of adjacent rotation pictures recorded at a fixed X-ray wavelength by an electronic area detector. The electronic pictures (data frames) covering the first 5° of crystal rotation are used to locate strong diffraction spots and to estimate the background. The orientation of the crystal is derived automatically from the list of observed spots and all parameters describing the diffraction pattern are refined. The only input required from the user is the specification of the space group, approximate cell dimensions and detector setting. When the initialization step is finished the program goes back to the first picture and evaluates all data frames in the order they arrive from the measurement. Each element of an electronic picture (pixel) is labelled by the indices of the nearest reflection using the current refined parameters describing the diffraction geometry. If the pixels close to its nearest reflection the counts contribute to the three-dimensional profile; otherwise the counts are used to update the background. Each profile is represented as if the reflection had followed the shortest path through the Ewald sphere and had been recorded on the surface of the sphere. Reflections close to the Ewald sphere are kept in a hash table to allow rapid access for updating the profiles. Reflections which have completely passed through the Ewald sphere are removed from the table and saved for further processing. Intensities are estimated by fitting their profiles to an average shape learned from strong neighbouring reflections. Smoothly varying scaling factors are applied to the Lp-corrected intensities which minimize discrepancies between symmetry-related reflections and fit to a reference data set if available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0021889888007903

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,505

Metadata

Authors
Kabsch, W.
Venue
Journal of Applied Crystallography
Published
1988-12-01
Volume
21
Issue
6
Pages
916-924
ISSN
0021-8898 (ISSN-L)
OpenAlex
W2161743998
Cited by
1,505
References
0
FWCI
12.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of single-crystal X-ray diffraction data from a position-sensitive detector. https://app.cochat.ai/papers/10.1107/s0021889888007903
The paper
Kabsch, W. (1988). Evaluation of single-crystal X-ray diffraction data from a position-sensitive detector. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889888007903

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.