SAXS experiments on absolute scale with Kratky systems using water as a secondary standard
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
For small-angle scattering, of X-rays (SAXS) and neutrons (SANS), the importance of absolute calibration has been recognized since the inception of the technique. The work reported here focuses on SAXS measurements using Kratky slit systems. In former days, only molecular weights or scattering per particle were determined, but today absolute calibration implies the use of the unit of cm−1 for the scattering curve. It is necessary to measure the so-called absolute intensity, which is the ratio of the scattering intensity to the primary intensity P0. Basically there are two possible ways to determine the absolute intensity. The first one is the direct method, which involves the mechanical attenuation of the primary beam by a rotating disc or a moving slit. The second is the indirect method, using secondary standards. Water is well suited as a calibration standard because of the angle-independent scattering. The essential advantage is that the scattering of water only depends on the physical property of isothermal compressibility. Before presenting an example of the practical performance of this method, the most important theoretical equations for an SAS experiment on the absolute scale are summarized. With the slit collimation system, the scattering curve of water can be measured with high enough statistical accuracy. As a first example, the scattering curve of the protein lysozyme on the absolute scale is presented. The second example is the determination of the aggregation number of a triblock copolymer P94 (EO 17–PO 42–EO 17). Taking into account that at least 10% of the polymer sample consists of diblocks, the accuracy of around 10% for the determined aggregation number is rather good. The data of P94 are also considered on the particle scale in order to obtain the radial scattering-length density distribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Small-Angle Scattering of X-Rays
Guinier, A., Fournet, G., Walker, C. B., & Vineyard, G. H. (1956) · Physics Today · doi:10.1063/1.3060069 · Cited by 4,310
A new method for the evaluation of small-angle scattering data
Glatter, O. (1977) · Journal of Applied Crystallography · doi:10.1107/s0021889877013879 · Cited by 1,279
Self-citationAbsolute calibration of small-angle neutron scattering data
Wignall, G. D., & Bates, F. S. (1987) · Journal of Applied Crystallography · doi:10.1107/s0021889887087181 · Cited by 733
Scattering Functions of Semiflexible Polymers with and without Excluded Volume Effects
Pedersen, J. S., & Schurtenberger, P. (1996) · Macromolecules · doi:10.1021/ma9607630 · Cited by 587
Chen, S. H. (1986) · Annual Review of Physical Chemistry · doi:10.1146/annurev.pc.37.100186.002031 · Cited by 463
Modern Aspects of Small-Angle Scattering
(1995) · Springer eBooks · doi:10.1007/978-94-015-8457-9 · Cited by 408
Brunner-Popela, J., & Glatter, O. (1997) · Journal of Applied Crystallography · doi:10.1107/s0021889896015749 · Cited by 291
Self-citationGlatter, O. (1981) · Journal of Applied Crystallography · doi:10.1107/s002188988100887x · Cited by 229
Self-citationImprovements in real-space deconvolution of small-angle scattering data
Glatter, O., & Hainisch, B. (1984) · Journal of Applied Crystallography · doi:10.1107/s0021889884011894 · Cited by 173
Self-citationSchurtenberger, P., Jerke, G., Cavaco, C., & Pedersen, J. S. (1996) · Langmuir · doi:10.1021/la9507444 · Cited by 64
Kratky, O., & Schwarzkopf-Schier, K. (1963) · Monatshefte für Chemie - Chemical Monthly · doi:10.1007/bf00913075 · Cited by 11
Cited by
Franke, D., Petoukhov, M. V., Konarev, P. V., Panjkovich, A., Tuukkanen, A., Mertens, H. D. T., Kikhney, A. G., Hajizadeh, N. R., Franklin, J. M., Jeffries, C. M., et al. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717007786 · Cited by 1,329
Characterization and Analysis of Porosity and Pore Structures
Anovitz, L. M., & Cole, D. R. (2015) · Reviews in Mineralogy and Geochemistry · doi:10.2138/rmg.2015.80.04 · Cited by 1,090
Small-angle scattering studies of biological macromolecules in solution
Svergun, D. I., & Koch, M. H. J. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/10/r05 · Cited by 1,014
Small Angle X-ray Scattering for Nanoparticle Research
Li, T., Senesi, A. J., & Lee, B. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00690 · Cited by 975
ATSAS 3.0: expanded functionality and new tools for small-angle scattering data analysis
Manalastas-Cantos, K., Konarev, P. V., Hajizadeh, N. R., Kikhney, A. G., Petoukhov, M. V., Molodenskiy, D. S., Panjkovich, A., Mertens, H. D. T., Gruzinov, A., Borges, C., et al. (2021) · Journal of Applied Crystallography · doi:10.1107/s1600576720013412 · Cited by 964
Metadata
- Authors
- Orthaber, D., Bergmann, A., & Glatter, O.
- Venue
- Journal of Applied Crystallography
- Published
- 2000-04-01
- Volume
- 33
- Issue
- 2
- Pages
- 218-225
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2070395446
- Cited by
- 607
- References
- 11
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.