New analytical scattering-factor functions for free atoms and ions
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
New analytical X-ray scattering-factor representations valid for the full range of sin Θ/λ from 0.0 to 6.0 Å−1 have been developed from fits of a linear combination of five Gaussians to the values of the scattering factors tabulated in International Tables for Crystallography (1992) [Vol. C. Dordrecht: Kluwer Academic Publishers]. The resulting functions for both neutral atoms and ions are compared with the existing parametrizations, which are applicable for 0.0–2.0 Å−1 and 2.0–6.0 Å−1, respectively. The quality of the new parametrization involving 11 parameters per atom (ion) compares well with the previous work or is even superior. Examples are discussed, some errors in International Tables for Crystallography, Vol. C are indicated and a warning is given that most of the previously published four Gaussian expansions for ions are inadequate for calculations involving sin Θ/λ ≥ 2.0 Å−1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Tables for X-ray Crystallography
(1976) · Acta Crystallographica Section B Structural Crystallography and Crystal Chemistry · doi:10.1107/s0567740876006080 · Cited by 14,214
Cited by
VESTA 3 for three-dimensional visualization of crystal, volumetric and morphology data
Momma, K., & Izumi, F. (2011) · Journal of Applied Crystallography · doi:10.1107/s0021889811038970 · Cited by 26,054
Towards automated crystallographic structure refinement with phenix.refine
Afonine, P. V., Grosse-Kunstleve, R. W., Echols, N., Headd, J. J., Moriarty, N. W., Mustyakimov, M., Terwilliger, T. C., Urzhumtsev, A., Zwart, P. H., & Adams, P. D. (2012) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444912001308 · Cited by 5,511
“Various X-ray and neutron scattering dictionaries are available (Neutron News, 1992; Maslen et al., 1992; Waasmaier & Kirfel, 1995; Grosse-Kunstleve, Sauter et al., 2004). phenix.refine uses a very efficient and robust algorithm for finding the best values for ksol, Bsol and Ucryst.”
MethodReal-space refinement in PHENIX for cryo-EM and crystallography
Afonine, P. V., Poon, B. K., Read, R. J., Sobolev, O. V., Terwilliger, T. C., Urzhumtsev, A., & Adams, P. D. (2018) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798318006551 · Cited by 3,281
First-principles Phonon Calculations with Phonopy and Phono3py
Togo, A. (2023) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.92.012001 · Cited by 1,865
The Scherrer equation and the dynamical theory of X-ray diffraction
Muniz, F. T. L., Miranda, M. A. R., Morilla dos Santos, C., & Sasaki, J. M. (2016) · Acta Crystallographica Section A Foundations and Advances · doi:10.1107/s205327331600365x · Cited by 989
Metadata
- Authors
- Waasmaier, D., & Kirfel, A.
- Venue
- Acta Crystallographica Section A Foundations of Crystallography
- Published
- 1995-05-01
- Volume
- 51
- Issue
- 3
- Pages
- 416-431
- ISSN
- 0108-7673 (ISSN-L)
- OpenAlex
- W2118077786
- Cited by
- 643
- References
- 1
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.