The DOI matches its Crossref record.
A new least-squares refinement technique based on the fast Fourier transform algorithm
Abstract
A new atomic-parameters least-squares refinement method is presented which makes use of the fast Fourier transform algorithm at all stages of the computation. For large structures, the amount of computation is almost proportional to the size of the structure making it very attractive for large biological structures such as proteins. In addition the method has a radius of convergence of approximately 0.75 Å making it applicable at a very early stage of the structure-determination process. The method has been tested on hypothetical as well as real structures. The method has been used to refine the structure of insulin at 1.5 Å resolution, barium beauvuricin complex at 1.2 Å resolution, and myoglobin at 2 Å resolution. Details of the method and brief summaries of its applications are presented in the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kabsch, W., & Sander, C. (1983) · Biopolymers · doi:10.1002/bip.360221211 · Cited by 15,320
Towards automated crystallographic structure refinement with phenix.refine
Afonine, P. V., Grosse-Kunstleve, R. W., Echols, N., Headd, J. J., Moriarty, N. W., Mustyakimov, M., Terwilliger, T. C., Urzhumtsev, A., Zwart, P. H., & Adams, P. D. (2012) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444912001308 · Cited by 5,511
Efficient anisotropic refinement of macromolecular structures using FFT
Murshudov, G. N., Vagin, A. A., Lebedev, A., Wilson, K. S., & Dodson, E. J. (1999) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s090744499801405x · Cited by 936
Crystal structure of trp represser/operator complex at atomic resolution
Otwinowski, Z., Schevitz, R. W., Zhang, R.-G., Lawson, C. L., Joachimiak, A., Marmorstein, R. Q., Luisi, B. F., & Sigler, P. B. (1988) · Nature · doi:10.1038/335321a0 · Cited by 907
The Phenix software for automated determination of macromolecular structures
Adams, P. D., Afonine, P. V., Bunkóczi, G., Chen, V. B., Echols, N., Headd, J. J., Hung, L.-W., Jain, S., Kapral, G. J., Grosse Kunstleve, R. W., et al. (2011) · Methods · doi:10.1016/j.ymeth.2011.07.005 · Cited by 891
Metadata
- Authors
- Agarwal, R. C.
- Venue
- Acta Crystallographica Section A
- Published
- 1978-09-01
- Volume
- 34
- Issue
- 5
- Pages
- 791-809
- ISSN
- 0567-7394 (ISSN-L)
- OpenAlex
- W2110721623
- Cited by
- 193
- References
- 0
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new least-squares refinement technique based on the fast Fourier transform algorithm. https://app.cochat.ai/papers/10.1107/s0567739478001618
- The paper
- Agarwal, R. C. (1978). A new least-squares refinement technique based on the fast Fourier transform algorithm. Acta Crystallographica Section A. https://doi.org/10.1107/s0567739478001618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.