The DOI matches its Crossref record.
Fitting atomic models into electron-microscopy maps
Open accessAbstract
Combining X-ray crystallographically determined atomic structures of component domains or subunits with cryo-electron microscopic three-dimensional images at around 22 Å resolution can produce structural information that is accurate to about 2.2 Å resolution. In an initial step, it is necessary to determine accurately the absolute scale and absolute hand of the cryo-electron microscopy map, the former of which can be off by up to 5%. It is also necessary to determine the relative height of density by using a suitable scaling function. Difference maps can identify, for instance, sites of glycosylation, the position of which helps to fit the component structures into the EM density maps. Examples are given from the analysis of alphaviruses, rhinovirus–receptor interactions and poliovirus–receptor interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Real-space refinement in PHENIX for cryo-EM and crystallography
Afonine, P. V., Poon, B. K., Read, R. J., Sobolev, O. V., Terwilliger, T. C., Urzhumtsev, A., & Adams, P. D. (2018) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798318006551 · Cited by 3,281
Kuhn, R. J., Zhang, W., Rossmann, M. G., Pletnev, S. V., Corver, J., Lenches, E., Jones, C. T., Mukhopadhyay, S., Chipman, P. R., Strauss, E. G., et al. (2002) · Cell · doi:10.1016/s0092-8674(02)00660-8 · Cited by 1,563
Self-citationPutnam, C. D., Hammel, M., Hura, G. L., & Tainer, J. A. (2007) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583507004635 · Cited by 1,184
Flexible Fitting of Atomic Structures into Electron Microscopy Maps Using Molecular Dynamics
Trabuco, L. G., Villa, E., Mitra, K., Frank, J., & Schulten, K. (2008) · Structure · doi:10.1016/j.str.2008.03.005 · Cited by 864
Outcome of the first electron microscopy validation task force meeting
Henderson, R., Sali, A., Baker, M. L., Carragher, B., Devkota, B., Downing, K. H., Egelman, E. H., Feng, Z., Frank, J., Grigorieff, N., et al. (2012) · Structure · doi:10.1016/j.str.2011.12.014 · Cited by 505
Self-citation
Metadata
- Authors
- Rossmann, M. G.
- Venue
- Acta Crystallographica Section D Biological Crystallography
- Published
- 2000-10-01
- Volume
- 56
- Issue
- 10
- Pages
- 1341-1349
- ISSN
- 0907-4449 (ISSN-L)
- OpenAlex
- W2128897252
- Cited by
- 189
- References
- 0
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fitting atomic models into electron-microscopy maps. https://app.cochat.ai/papers/10.1107/s0907444900009562
- The paper
- Rossmann, M. G. (2000). Fitting atomic models into electron-microscopy maps. Acta Crystallographica Section D Biological Crystallography. https://doi.org/10.1107/s0907444900009562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.