Recent advances in the CRANK software suite for experimental phasing
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
For its first release in 2004, CRANK was shown to effectively detect and phase anomalous scatterers from single-wavelength anomalous diffraction data. Since then, CRANK has been significantly improved and many more structures can be built automatically with single- or multiple-wavelength anomalous diffraction or single isomorphous replacement with anomalous scattering data. Here, the new algorithms that have been developed that have led to these substantial improvements are discussed and CRANK's performance on over 100 real data sets is shown. The latest version of CRANK is freely available for download at http://www.bfsc.leidenuniv.nl/software/crank/ and from CCP4 (http://www.ccp4.ac.uk/).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Automated macromolecular model building for X-ray crystallography using ARP/wARP version 7
Langer, G., Cohen, S. X., Lamzin, V. S., & Perrakis, A. (2008) · Nature Protocols · doi:10.1038/nprot.2008.91 · Cited by 1,606
Cited by
The PDB_REDO server for macromolecular structure model optimization
Joosten, R. P., Long, F., Murshudov, G. N., & Perrakis, A. (2014) · IUCrJ · doi:10.1107/s2052252514009324 · Cited by 834
Chamberlain, P. P., Lopez-Girona, A., Miller, K., Carmel, G., Pagarigan, B., Chie-Leon, B., Rychak, E., Corral, L. G., Ren, Y. J., Wang, M., et al. (2014) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.2874 · Cited by 531
Automatic protein structure solution from weak X-ray data
Skubák, P., & Pannu, N. S. (2013) · Nature Communications · doi:10.1038/ncomms3777 · Cited by 282
Self-citationPosttranslational modification of microtubules by the MATCAP detyrosinase
Landskron, L., Bak, J., Adamopoulos, A., Kaplani, K., Moraiti, M., van den Hengel, L. G., Song, J.-Y., Bleijerveld, O. B., Nieuwenhuis, J., Heidebrecht, T., et al. (2022) · Science · doi:10.1126/science.abn6020 · Cited by 78
“These sites were virtually identical to those detected by the same software in the context of the CRANK2pipeline (46).”
Conformational transitions of the Spindly adaptor underlie its interaction with Dynein and Dynactin
d’Amico, E. A., Ud Din Ahmad, M., Cmentowski, V., Girbig, M., Müller, F., Wohlgemuth, S., Brockmeyer, A., Maffini, S., Janning, P., Vetter, I. R., et al. (2022) · Journal of Cell Biology · doi:10.1083/jcb.202206131 · Cited by 34
Metadata
- Authors
- Pannu, N. S., Waterreus, W.-J., Skubák, P., Sikharulidze, I., Abrahams, J. P., & de Graaff, R. A. G.
- Venue
- Acta Crystallographica Section D Biological Crystallography
- Published
- 2011-03-18
- Volume
- 67
- Issue
- 4
- Pages
- 331-337
- ISSN
- 0907-4449 (ISSN-L)
- OpenAlex
- W2022382695
- Cited by
- 90
- References
- 1
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.