The crystallography beamline I711 at MAX II
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new X-ray crystallographic beamline is operational at the MAX II synchrotron in Lund. The beamline has been in regular use since August 1998 and is used both for macro- and small molecule diffraction as well as powder diffraction experiments. The radiation source is a 1.8 T multipole wiggler. The beam is focused vertically by a bendable mirror and horizontally by an asymmetrically cut Si(111) monochromator. The wavelength range is 0.8-1.55 A with a measured flux at 1 A of more than 10(11) photons s(-1) in 0.3 mm x 0.3 mm at the sample position. The station is currently equipped with a Mar345 imaging plate, a Bruker Smart 1000 area CCD detector and a Huber imaging-plate Guinier camera. An ADSC 210 area CCD detector is planned to be installed during 2000.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The protein data bank: A computer-based archival file for macromolecular structures
Bernstein, F. C., Koetzle, T. F., Williams, G. J. B., Meyer, E. F., Brice, M. D., Rodgers, J. R., Kennard, O., Shimanouchi, T., & Tasumi, M. (1977) · Journal of Molecular Biology · doi:10.1016/s0022-2836(77)80200-3 · Cited by 8,578 · cited 1×
“For example, Cambridge Structural Database (Allen, 1998) now includes almost 200000 entries on organic, organometallic and metal complexes and the number of structures deposited in the Protein Data Bank (Bernstein et al., 1977) has shown an almost exponential growth rate during the last years.”
BackgroundMacromolecular Crystallography with Synchrotron Radiation
Helliwell, J. R., & Smith, J. L. (1993) · Physics Today · doi:10.1063/1.2808939 · Cited by 173 · cited 2×
“The crystal is asymmetrically cut (presently a crystal with an asymmetric angle of 7 is used) which compresses the re¯ected beam compared with the incident beam and shortens the focal distance (Helliwell, 1992).”
Background
Cited by
Versatile in situ powder X-ray diffraction cells for solid–gas investigations
Jensen, T. R., Nielsen, T. K., Filinchuk, Y., Jørgensen, J.-E., Cerenius, Y., Gray, E. M., & Webb, C. J. (2010) · Journal of Applied Crystallography · doi:10.1107/s0021889810038148 · Cited by 163
“Setup for in situ experiments The experimental setup for the sapphire-based cell (A) is implemented at the MAX II synchrotron in the Swedish national research laboratory MAX-lab at beamline I711 (Cerenius et al., 2000).”
MethodSelf-citationStructure and Dynamics for LiBH4−LiCl Solid Solutions
Arnbjerg, L. M., Ravnsbæk, D. B., Filinchuk, Y., Vang, R. T., Cerenius, Y., Besenbacher, F., Jørgensen, J.-E., Jakobsen, H. J., & Jensen, T. R. (2009) · Chemistry of Materials · doi:10.1021/cm902013k · Cited by 158
Self-citationKarlberg, T., Schagerlöf, U., Gakh, O., Park, S., Ryde, U., Lindahl, M., Leath, K., Garman, E., Isaya, G., & Al-Karadaghi, S. (2006) · Structure · doi:10.1016/j.str.2006.08.010 · Cited by 85
Metadata
- Authors
- Cerenius, Y., Ståhl, K., Svensson, L. A., Ursby, T., Oskarsson, Å., Albertsson, J., & Liljas, A.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2000-07-01
- Volume
- 7
- Issue
- 4
- Pages
- 203-208
- ISSN
- 0909-0495 (ISSN-L)
- OpenAlex
- W2118079014
- Cited by
- 207
- References
- 2
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.