Geometrical fitting of experimental XANES spectra by a full multiple-scattering procedure
Open accessThe DOI matches its Crossref record.
Abstract
In this paper a new software procedure is presented, named MXAN, able to fit the XANES part (from the edge to about 200 eV) of experimental X-ray absorption data. The method is based on the fitting between the experimental spectrum and several theoretical calculations generated by changing the relevant geometrical parameters of the site around the absorbing atom. The X-ray photo-absorption cross section is calculated using the full multiple-scattering scheme; different choices of the exchange correlation part of the potential can be utilised. To show the potentialities of the method the analysis of the nickel K-edge of the nickel ion in aqueous solution is presented. The procedure is able to recover the correct information on the symmetry and atomic distances from the experimental Ni K-edge XANES spectrum. The recovered structure is found to be independent of the starting conditions, showing the theoretical uniqueness of the structural solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zitolo, A., Goellner, V., Armel, V., Sougrati, M.-T., Mineva, T., Stievano, L., Fonda, E., & Jaouen, F. (2015) · Nature Materials · doi:10.1038/nmat4367 · Cited by 2,123
Parameter-free calculations of X-ray spectra with FEFF9
Rehr, J. J., Kas, J. J., Vila, F. D., Prange, M. P., & Jorissen, K. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/b926434e · Cited by 1,216
Bordiga, S., Groppo, E., Agostini, G., van Bokhoven, J. A., & Lamberti, C. (2013) · Chemical Reviews · doi:10.1021/cr2000898 · Cited by 643
Zitolo, A., Ranjbar-Sahraie, N., Mineva, T., Li, J., Jia, Q., Stamatin, S., Harrington, G. F., Lyth, S. M., Krtil, P., Mukerjee, S., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01100-7 · Cited by 563
Sarma, B. B., Maurer, F., Doronkin, D. E., & Grunwaldt, J.-D. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00495 · Cited by 291
Photoinduced Structural Dynamics of Molecular Systems Mapped by Time-Resolved X-ray Methods
Chergui, M., & Collet, E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00831 · Cited by 261
EXAFS and XANES analysis of oxides at the nanoscale
Kuzmin, A., & Chaboy, J. (2014) · IUCrJ · doi:10.1107/s2052252514021101 · Cited by 254
Fabricating Single‐Atom Catalysts from Chelating Metal in Open Frameworks
Lin, Y., Liu, P., Velasco, E., Yao, G., Tian, Z., Zhang, L., & Chen, L. (2019) · Advanced Materials · doi:10.1002/adma.201808193 · Cited by 211
Torrisi, S. B., Carbone, M. R., Rohr, B. A., Montoya, J. H., Ha, Y., Yano, J., Suram, S. K., & Hung, L. (2020) · npj Computational Materials · doi:10.1038/s41524-020-00376-6 · Cited by 171
“At their current accuracies and ef fi ciencies, models developed within this work could be used as a pre-processing step into these more rigorous work fl ows — those involving FEFF, MXAN, or Py fi tit — to narrow down initial guesses for a chemical structure when no a priori structure knowledge is available 41 – 45 .”
MethodInfluentialCharacterization of “spectroscopically quiet” metals in biology
Penner-Hahn, J. E. (2005) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2004.03.011 · Cited by 163
Molecular Structural Dynamics Probed by Ultrafast X-Ray Absorption Spectroscopy
Bressler, C., & Chergui, M. (2010) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103353 · Cited by 162
Chen, L. X., Zhang, X., Lockard, J. V., Stickrath, A. B., Attenkofer, K., Jennings, G., & Liu, D.-J. (2010) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767309051496 · Cited by 88
Metadata
- Authors
- Benfatto, M., & Della Longa, S.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2001-06-20
- Volume
- 8
- Issue
- 4
- Pages
- 1087-1094
- ISSN
- 0909-0495 (ISSN-L)
- OpenAlex
- W1997208482
- Cited by
- 193
- References
- 0
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.