CoChat

I18 – the microfocus spectroscopy beamline at the Diamond Light Source

Open access
Mosselmans, J. Frederick W., Quinn, Paul D., Dent, Andrew J., Cavill, Stuart A., Moreno, Sofia Diaz, Peach, Andrew, Leicester, Peter J., Keylock, Stephen J., Gregory, Simon R., Atkinson, Kirk D., Rosell, Josep Roque · 2009 · Journal of Synchrotron Radiation
Cited by 169

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The design and performance of the microfocus spectroscopy beamline at the Diamond Light Source are described. The beamline is based on a 27 mm-period undulator to give an operable energy range between 2 and 20.7 keV, enabling it to cover the K-edges of the elements from P to Mo and the L(3)-edges from Sr to Pu. Micro-X-ray fluorescence, micro-EXAFS and micro-X-ray diffraction have all been achieved on the beamline with a spot size of approximately 3 microm. The principal optical elements of the beamline consist of a toroid mirror, a liquid-nitrogen-cooled double-crystal monochromator and a pair of bimorph Kirkpatrick-Baez mirrors. The performance of the optics is compared with theoretical values and a few of the early experimental results are summarized.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0909049509032282

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • ATHENA,ARTEMIS,HEPHAESTUS: data analysis for X-ray absorption spectroscopy using IFEFFIT

    Ravel, B., & Newville, M. (2005) · Journal of Synchrotron Radiation · doi:10.1107/s0909049505012719 · Cited by 16,965 · cited 1×

    “The EXAFS was reduced using the program Athena (Ravel & Newville, 2005), where a selfabsorption correction was made and fitted in the program DLExcurv (Tomic et al., 2005).”
    Method
  • Formation of Optical Images by X-Rays

    Kirkpatrick, P. H., & Baez, A. V. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000766 · Cited by 1,396 · cited 1×

    “The final focusing of the beam is achieved by a Kirkpatrick– Baez (KB) (Kirkpatrick & Baez, 1948) system (Oxford Danfysik).”
    Method
  • Confined Plasmons in Metallic Nanocavities

    Coyle, S., Netti, M. C., Baumberg, J. J., Ghanem, M. A., Birkin, P. R., Bartlett, P. N., & Whittaker, D. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.176801 · Cited by 208 · cited 1×

    “A wide variety of functional materials can be patterned into such antidot arrays, including magnetic and superconducting metals (Coyle et al., 2001).”
    Background
  • LUCIA, a microfocus soft XAS beamline

    Flank, A.-M., Cauchon, G., Lagarde, P., Bac, S., Janousch, M., Wetter, R., Dubuisson, J.-M., Idir, M., Langlois, F., Moreno, T., et al. (2006) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2005.12.007 · Cited by 194 · cited 1×

    “Microfocus spectroscopy beamlines are becoming increasingly important for the analysis of heterogeneous materials in all fields of science in microscopic detail (e.g. Evans, 2006; Flank et al., 2006; Kemner, 2008; Scheidegger et al., 2006).”
    Background
  • The use of (micro)-X-ray absorption spectroscopy in cement research

    Scheidegger, A. M., Vespa, M., Grolimund, D., Wieland, E., Harfouche, M., Bonhoure, I., & Dähn, R. (2006) · Waste Management · doi:10.1016/j.wasman.2006.01.032 · Cited by 15 · cited 1×

    “Microfocus spectroscopy beamlines are becoming increasingly important for the analysis of heterogeneous materials in all fields of science in microscopic detail (e.g. Evans, 2006; Flank et al., 2006; Kemner, 2008; Scheidegger et al., 2006).”
    Background

Cited by

See all 169

Metadata

Authors
Mosselmans, J. F. W., Quinn, P. D., Dent, A. J., Cavill, S. A., Moreno, S. D., Peach, A., Leicester, P. J., Keylock, S. J., Gregory, S. R., Atkinson, K. D., & Rosell, J. R.
Venue
Journal of Synchrotron Radiation
Published
2009-09-10
Volume
16
Issue
6
Pages
818-824
ISSN
0909-0495 (ISSN-L)
OpenAlex
W1990791688
Cited by
169
References
5
FWCI
7.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.