Fully automatic characterization and data collection from crystals of biological macromolecules
Open accessThe DOI matches its Crossref record.
Abstract
Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to the optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The structural basis for cohesin–CTCF-anchored loops
Li, Y., Haarhuis, J. H. I., Sedeño Cacciatore, Á., Oldenkamp, R., van Ruiten, M. S., Willems, L., Teunissen, H., Muir, K. W., de Wit, E., Rowland, B. D., et al. (2020) · Nature · doi:10.1038/s41586-019-1910-z · Cited by 459
Molecular basis of β-arrestin coupling to formoterol-bound β1-adrenoceptor
Lee, Y., Warne, T., Nehmé, R., Pandey, S., Dwivedi-Agnihotri, H., Chaturvedi, M., Edwards, P. C., García-Nafría, J., Leslie, A. G. W., Shukla, A. K., et al. (2020) · Nature · doi:10.1038/s41586-020-2419-1 · Cited by 295
Bowler, M. W., Nurizzo, D., Barrett, R., Beteva, A., Bodin, M., Caserotto, H., Delagenière, S., Dobias, F., Flot, D., Giraud, T., et al. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515016604 · Cited by 173
“In combination with the LIMS ISPyB (Delageniè re et al., 2011) and workflows for the automation of data analysis (Brockhauser et al., 2012; Bourenkov & Popov, 2010; Incardona et al., 2009), a fully automatic system has been developed to mount, locate, centre to the optimal diffraction volume, characterize and collect,…”
InfluentialSelf-citationCharacterization of aquaporin-driven hydrogen peroxide transport
Wang, H., Schoebel, S., Schmitz, F., Dong, H., & Hedfalk, K. (2020) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2019.183065 · Cited by 107
Structural basis of STAT2 recognition by IRF9 reveals molecular insights into ISGF3 function
Rengachari, S., Groiss, S., Devos, J. M., Caron, E., Grandvaux, N., & Panne, D. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718426115 · Cited by 91
Metadata
- Authors
- Svensson, O., Malbet-Monaco, S., Popov, A., Nurizzo, D., & Bowler, M. W.
- Venue
- Acta Crystallographica Section D Biological Crystallography
- Published
- 2015-07-31
- Volume
- 71
- Issue
- 8
- Pages
- 1757-1767
- ISSN
- 0907-4449 (ISSN-L)
- 1399-0047
- OpenAlex
- W1893111942
- Cited by
- 118
- References
- 0
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully automatic characterization and data collection from crystals of biological macromolecules. https://app.cochat.ai/papers/10.1107/s1399004715011918
- The paper
- Svensson, O., Malbet-Monaco, S., Popov, A., Nurizzo, D., & Bowler, M. W. (2015). Fully automatic characterization and data collection from crystals of biological macromolecules. Acta Crystallographica Section D Biological Crystallography. https://doi.org/10.1107/s1399004715011918
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.