Quick-EXAFS setup at the SuperXAS beamline for in situ X-ray absorption spectroscopy with 10 ms time resolution
Open accessAbstract
The quick-EXAFS (QEXAFS) method adds time resolution to X-ray absorption spectroscopy (XAS) and allows dynamic structural changes to be followed. A completely new QEXAFS setup consisting of monochromator, detectors and data acquisition system is presented, as installed at the SuperXAS bending-magnet beamline at the Swiss Light Source (Paul Scherrer Institute, Switzerland). The monochromator uses Si(111) and Si(311) channel-cut crystals mounted on one crystal stage, and remote exchange allows an energy range from 4.0 keV to 32 keV to be covered. The spectral scan range can be electronically adjusted up to several keV to cover multiple absorption edges in one scan. The determination of the Bragg angle close to the position of the crystals allows high-accuracy measurements. Absorption spectra can be acquired with fast gridded ionization chambers at oscillation frequencies of up to 50 Hz resulting in a time resolution of 10 ms, using both scan directions of each oscillation period. The carefully developed low-noise detector system yields high-quality absorption data. The unique setup allows both state-of-the-art QEXAFS and stable step-scan operation without the need to exchange whole monochromators. The long-term stability of the Bragg angle was investigated and absorption spectra of reference materials as well as of a fast chemical reaction demonstrate the overall capabilities of the new setup.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fabbri, E., Nachtegaal, M., Binninger, T., Cheng, X., Kim, B.-J., Durst, J., Bozza, F., Graule, T., Schäublin, R., Wiles, L., et al. (2017) · Nature Materials · doi:10.1038/nmat4938 · Cited by 1,064
Self-citationIn Situ/Operando Electrocatalyst Characterization by X-ray Absorption Spectroscopy
Timoshenko, J., & Roldan Cuenya, B. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00396 · Cited by 931
Abbott, D. F., Lebedev, D., Waltar, K., Povia, M., Nachtegaal, M., Fabbri, E., Copéret, C., & Schmidt, T. J. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.6b02625 · Cited by 492
Self-citationIn situ/operando synchrotron-based X-ray techniques for lithium-ion battery research
Bak, S.-M., Shadike, Z., Lin, R., Yu, X., & Yang, X.-Q. (2018) · NPG Asia Materials · doi:10.1038/s41427-018-0056-z · Cited by 403
Progress of Nonprecious‐Metal‐Based Electrocatalysts for Oxygen Evolution in Acidic Media
Gao, J., Tao, H., & Liu, B. (2021) · Advanced Materials · doi:10.1002/adma.202003786 · Cited by 381
Metadata
- Authors
- Müller, O., Nachtegaal, M., Just, J., Lützenkirchen-Hecht, D., & Frahm, R.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2016-01-01
- Volume
- 23
- Issue
- 1
- Pages
- 260-266
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W2258973119
- Cited by
- 210
- References
- 0
- FWCI
- 14.39
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quick-EXAFS setup at the SuperXAS beamline for in situ X-ray absorption spectroscopy with 10 ms time resolution. https://app.cochat.ai/papers/10.1107/s1600577515018007
- The paper
- Müller, O., Nachtegaal, M., Just, J., Lützenkirchen-Hecht, D., & Frahm, R. (2016). Quick-EXAFS setup at the SuperXAS beamline for in situ X-ray absorption spectroscopy with 10 ms time resolution. Journal of Synchrotron Radiation. https://doi.org/10.1107/s1600577515018007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.