VMXi: a fully automated, fully remote, high-flux in situ macromolecular crystallography beamline
Open accessThe DOI matches its Crossref record.
Abstract
VMXi is a new high-flux microfocus macromolecular crystallography beamline at Diamond Light Source. The beamline, dedicated to fully automated and fully remote data collection of macromolecular crystals in situ , allows rapid screening of hundreds of crystallization plates from multiple user groups. Its main purpose is to give fast feedback at the complex stages of crystallization and crystal optimization, but it also enables data collection of small and delicate samples that are particularly difficult to harvest using conventional cryo-methods, crystals grown in the lipidic cubic phase, and allows for multi-crystal data collections in drug discovery programs. The beamline is equipped with two monochromators: one with a narrow band-pass and fine energy resolution (optimal for regular oscillation experiments), and one with a wide band-pass and a high photon flux (optimal for fast screening). The beamline has a state-of-the-art detector and custom goniometry that allows fast data collection. This paper describes the beamline design, current status and future plans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Beilsten-Edmands, J., Winter, G., Gildea, R., Parkhurst, J., Waterman, D., & Evans, G. (2020) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798320003198 · Cited by 159
“Diffraction data were collected on beamline I03 at Diamond Light Source, consisting of 7200 images at 0.1 intervals, following a low-dose high-multiplicity strategy (Winter & McAuley, 2016).”
BackgroundMethodInfluentialRoom-temperature crystallography reveals altered binding of small-molecule fragments to PTP1B
Skaist Mehlman, T., Biel, J. T., Azeem, S. M., Nelson, E. R., Hossain, S., Dunnett, L., Paterson, N. G., Douangamath, A., Talon, R., Axford, D., et al. (2023) · eLife · doi:10.7554/elife.84632 · Cited by 84
Structural basis for the ligand-dependent activation of heterodimeric AHR-ARNT complex
Diao, X., Shang, Q., Guo, M., Huang, Y., Zhang, M., Chen, X., Liang, Y., Sun, X., Zhou, F., Zhuang, J., et al. (2025) · Nature communications · doi:10.1038/s41467-025-56574-7 · Cited by 72
Matsuura, H., Sakai, N., Toma-Fukai, S., Muraki, N., Hayama, K., Kamikubo, H., Aono, S., Kawano, Y., Yamamoto, M., & Hirata, K. (2023) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798323007039 · Cited by 14
King, O. N. F., Levik, K. E., Sandy, J., & Basham, M. (2024) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798324009276 · Cited by 5
Self-citation
Metadata
- Authors
- Sanchez-Weatherby, J., Sandy, J., Mikolajek, H., Lobley, C. M. C., Mazzorana, M., Kelly, J., Preece, G., Littlewood, R., & Sørensen, T. L.-M.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2019-01-01
- Volume
- 26
- Issue
- 1
- Pages
- 291-301
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W2901213304
- Cited by
- 57
- References
- 0
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: VMXi: a fully automated, fully remote, high-flux in situ macromolecular crystallography beamline. https://app.cochat.ai/papers/10.1107/s1600577518015114
- The paper
- Sanchez-Weatherby, J., Sandy, J., Mikolajek, H., Lobley, C. M. C., Mazzorana, M., Kelly, J., Preece, G., Littlewood, R., & Sørensen, T. L.-M. (2019). VMXi: a fully automated, fully remote, high-flux in situ macromolecular crystallography beamline. Journal of Synchrotron Radiation. https://doi.org/10.1107/s1600577518015114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.