The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A novel method for angle independent ultrasonic imaging of blood flow and tissue motion
Abstract
Tracking the speckle patterns produced by moving targets has been shown effective for angle independent imaging of blood flow and tissue motion. While speckle tracking overcomes major limitations of Doppler-based flow imaging, the computational complexity of commonly used cross correlation algorithms currently limits it to off-line studies. A much simpler algorithm for angle independent motion imaging is described in this paper. This method requires only one absolute difference operation per pixel, compared to eight operations for normalized cross correlation. Quantitative studies using speckle-generating targets translated by fixed amounts both axially and laterally indicate that the technique tracks moving speckle as accurately as correlation. Color flow images generated from clinical blood and liver data highlight the success of the technique for tracking both large and small motions in two dimensions. The algorithm's suitability for implementation in digital hardware makes possible the development of clinical instruments for angle independent ultrasonic imaging of blood flow and tissue motion in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · Sensor Review · doi:10.1108/sr.1999.08719bae.001 · Cited by 6,021
A Class of Algorithms for Fast Digital Image Registration
Barnea, D. I., & Silverman, H. F. (1972) · IEEE Transactions on Computers · doi:10.1109/tc.1972.5008923 · Cited by 970
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Self-citationDoppler Ultrasound: Physics, Instrumentation and Clinical Applications
Ritenour, E. R. (1990) · Radiology · doi:10.1148/radiology.177.2.346 · Cited by 289
Fundamental correlation lengths of coherent speckle in medical ultrasonic images
Wagner, R. F., Insana, M. F., & Smith, S. W. (1988) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.4145 · Cited by 222
Cardiac imaging using a phased array ultrasound system. I. System design.
vonRamm, O. T., & Thurstone, F. L. (1976) · Circulation · doi:10.1161/01.cir.53.2.258 · Cited by 186
A New Velocity Estimator for Color Flow Mapping
Bonnefous, O., Pesque, P., & Bernard, X. (1986) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1986.198856 · Cited by 60
Cited by
Dalen, H., Thorstensen, A., Aase, S. A., Ingul, C. B., Torp, H., Vatten, L. J., & Stoylen, A. (2010) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ejechocard/jep194 · Cited by 356
Routh, H. F. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.544510 · Cited by 63
Metadata
- Authors
- Bohs, L. N., & Trahey, G. E.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991-03
- Volume
- 38
- Issue
- 3
- Pages
- 280-286
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2100194764
- Cited by
- 438
- References
- 7
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel method for angle independent ultrasonic imaging of blood flow and tissue motion. https://app.cochat.ai/papers/10.1109/10.133210
- The paper
- Bohs, L. N., & Trahey, G. E. (1991). A novel method for angle independent ultrasonic imaging of blood flow and tissue motion. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.133210
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.