The DOI matches its Crossref record.
Adaptive Fourier estimation of time-varying evoked potentials
Abstract
An estimation procedure for dealing with time-varying evoked potentials is presented here. The evoked response is modeled as a dynamic Fourier series and the Fourier coefficients are estimated adaptively by the least mean square algorithm. Approximate expressions have been developed for the estimation error and time constant of adaptation. A procedure for optimizing the estimator performance is also presented. The effectiveness of the estimator in dealing with simulated as well as actual evoked responses is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 15
- vaz, 1987, Evoked potential estimation using a Fourier scries model, Proc 9th Ann Conf IEEE Eng Med Biol, 600
- 10.1109/TAC.1983.1103143 · DOI
- 10.1109/TASSP.1985.1164493 · DOI · Paper page
- 10.1097/00000542-198612000-00004 · DOI
- heinze, 1984, ARMA-Filtering of evoked potentials, Meth Inform Med, 23, 29, 10.1055/s-0038-1635318 · doi:10.1055/s-0038-1635318
- 10.1109/CDC.1987.272822 · doi:10.1109/cdc.1987.272822
- 10.1109/TCS.1981.1085012 · DOI
- thakor, 1985, Improved SNR in evoked potentials by adaptive filtering, Proc VII Ann Conf IEEE/EMBS, il, 112
- walter, 1969, A posteriori 'Wiener filtering' of average evoked responses, Electroencephalogr Clin Neurophysiol, 27, 61
- widrow, 1985, Adaptive Signal Processing
- 10.1109/TBME.1983.325187 · doi:10.1109/tbme.1983.325187
- de weerd, 1981, A posteriori time-varying filtering of average evoked potentials, Biol Cybern, 41, 211, 10.1007/BF00340322 · DOI
- 10.1016/B978-0-12-788284-0.50023-1 · DOI
- mcgillem, 1981, Critical Reviews in Bioengineering, 225
- 10.1016/0168-5597(85)90046-2 · doi:10.1016/0168-5597(85)90046-2
Cited by
Principal Component Analysis in ECG Signal Processing
Castells, F., Laguna, P., Sörnmo, L., Bollmann, A., & Roig, J. M. (2007) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2007/74580 · Cited by 371
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260
Self-citationModeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114
Self-citationAn adaptive estimation of periodic signals using a Fourier linear combiner
Vaz, C., Kong, X., & Thakor, N. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.258116 · Cited by 108
Self-citationAdaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83
Self-citation
Metadata
- Authors
- Vaz, C. A., & Thakor, N. V.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989-04
- Volume
- 36
- Issue
- 4
- Pages
- 448-455
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2022597732
- Cited by
- 159
- References
- 0
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive Fourier estimation of time-varying evoked potentials. https://app.cochat.ai/papers/10.1109/10.18751
- The paper
- Vaz, C. A., & Thakor, N. V. (1989). Adaptive Fourier estimation of time-varying evoked potentials. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.18751
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.