CoChat

Modeling the neuron-microtransducer junction: from extracellular to patch recording

Grattarola, M., Martinoia, S. · 1993 · IEEE Transactions on Biomedical Engineering
Cited by 95

The DOI matches its Crossref record.

Abstract

This paper is devoted to a detailed characterization of the neuron-to-microtransducer junction, based on the equivalent electric-circuit approach. As a result, recording of action potentials can be simulated with the general-purpose network-analysis program SPICE. Both noble-metal microelectrodes and insulated-gate FET's are considered. The responses of such devices are characterized as functions of several parameters, e.g., sealing impedance, density of ionic currents in the cell membrane, and spatial discontinuities of the adhesion process. It is shown that the various signal shapes reported in the literature can be reproduced and interpreted in terms of time derivatives of the action potential. In this way, the shape of any experimental signal can be interpreted on the basis of a specific sealing condition. Possible future improvements in microtransducer design, based on the proposed approach, are also suggested.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.204769

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Grattarola, M., & Martinoia, S.
Venue
IEEE Transactions on Biomedical Engineering
Published
1993
Volume
40
Issue
1
Pages
35-41
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2105899130
Cited by
95
References
0
FWCI
0.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.