Transformation of multichannel magnetocardiographic signals to standard grid form
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Multichannel magnetocardiographic (MCG) recordings with fixed sensor arrays are not directly comparable with single-channel measurements carried out at standard grid locations. In addition, comparison of data obtained with different types of magnetometers is difficult. We present a method for transforming multichannel measurements to the standard-grid format. The minimum-norm estimate (MNE) of the source current distribution in the body is calculated, and the desired field components in standard grid points are then computed from the MNE. We measured three subjects with both a 24-channel and a single-channel instrument. The signals extrapolated from the multichannel measurements corresponded quite well to the single-channel data registered at the standard grid locations, especially in those grid points that were covered by the 24-channel device. The signal-amplitude-weighted correlations between the extrapolated and directly measured signals were 0.73-0.87. In simulations with ideal measurement geometry but with a realistic amount of random noise in the signals, we obtained a 0.99 correlation. It was also found that the method is relatively tolerant to errors in the location and orientation of the multichannel magnetometer. For example, a simulated 20-mm displacement in the location of the sensor array caused only a 3% decrease in the correlation, and when it was rotated and tilted by 10 degrees C, the correlation decreased by 5%. The basic advantage of our extrapolation method is its physiologic nature: the method is based on the mathematical modeling of the source current distribution, rather than on direct constraints applied to the magnetic field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Self-citation
Cited by
Applications of the signal space separation method
Taulu, S., Simola, J., & Kajola, M. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853302 · Cited by 548
Involuntary Motor Activity in Pianists Evoked by Music Perception
Haueisen, J., & Knösche, T. R. (2001) · Journal of Cognitive Neuroscience · doi:10.1162/08989290152541449 · Cited by 363
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Bilateral activation of the human somatomotor cortex by distal hand movements
Salmelin, R., Forss, N., Knuutila, J., & Hari, R. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00193-x · Cited by 158
BROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99
Metadata
- Authors
- Numminen, J., Ahlfors, S., Ilmoniemi, R., Montonen, J., & Nenonen, J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1995
- Volume
- 42
- Issue
- 1
- Pages
- 72-78
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2149690770
- Cited by
- 71
- References
- 1
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.