Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 185

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Reducing muscle fatigue in FES applications by stimulating with N-let pulse trains

Karu, Z.Z., Durfee, W.K., Barzilai, A.M. · 1995 · IEEE Transactions on Biomedical Engineering

Abstract

Applications of electrical stimulation for restoration of functional movements such as standing, gait, and grasp have always been hindered by the rapid fatigue of stimulated muscle. This paper describes an experimental investigation of stimulation with N-lets (a set of N closely spaced stimulation pulses) as a means of producing contractions with improved fatigue characteristics. Experiments were conducted on 27 able-bodied and four SCI human subjects using surface stimulation of the quadriceps muscle to produce isometric knee joint torque. Based upon evidence from the literature on muscle fatigue, parameters of the N-let trains for N = 1-6 were optimized to produce the most force per pulse. The results demonstrated that: 1) nonlinear summation of the twitch response occurs in human subjects with N-let surface stimulation; 2) for most subjects, doublet stimulation (N = 2) with a pulse interval of about 5 ms produced the maximum torque-time integral per pulse of the resulting twitch; and 3) on average, optimal N-let stimulation resulted in a 36% increase in isometric torque tracking when compared to traditional singlet stimulation. The results have immediate implications for alleviating the problem of premature fatigue during functional electrical stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.398642

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 185

Metadata

Authors
Karu, Z. Z., Durfee, W. K., & Barzilai, A. M.
Venue
IEEE Transactions on Biomedical Engineering
Published
1995
Volume
42
Issue
8
Pages
809-817
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2100082290
Cited by
185
References
5
FWCI
5.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.