The DOI matches its Crossref record.
A mathematical model of make and break electrical stimulation of cardiac tissue by a unipolar anode or cathode
Abstract
Numerical simulations of electrical stimulation of cardiac tissue using a unipolar extracellular electrode were performed. The bidomain model with unequal anisotropy ratios represented the tissue, and the Beeler-Reuter model represented the active membrane properties. Four types of excitation were considered: cathode make (CM), anode make (AM), cathode break (CB), and anode break (AB). The mechanisms of excitation were: for CM, tissue under the cathode was depolarized to threshold; for AM, tissue at a virtual cathode was depolarized to threshold; for CB, a long cathodal pulse produced a steady-state depolarization under the cathode and hyperpolarization at a virtual anode. At the end (break) of the pulse, the depolarization diffused into the hyperpolarized tissue, resulting in excitation. For AB, a long anodal pulse produced a steady-state hyperpolarization under the anode and depolarization at a virtual cathode. At the end (break) of the pulse, the depolarization diffused into the hyperpolarized tissue, resulting in excitation. For AB stimulation, decay of the hyperpolarization faster than that of the depolarization was necessary. The thresholds for rheobase and diastolic CM, AM, CB, and AB stimulation were 0.038, 0.41, 0.49, and 5.3 mA, respectively, for an electrode length of 1 mm and a surface area of 1.5 mm2. Threshold increased as the size of the electrode increased. The strength-duration curves for CM and AM were similar except when the duration was shorter than 0.2 ms, in which case the AM threshold rose more quickly with decreasing duration than did the CM threshold. CM and AM resulted in similar strength-frequency curves. The model agrees qualitatively, but (in some cases) not quantitatively, with experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tagantsev, A. K., Stolichnov, I., Colla, E. L., & Setter, N. (2001) · Journal of Applied Physics · doi:10.1063/1.1381542 · Cited by 602
Virtual Electrode–Induced Phase Singularity: A Basic Mechanism of Defibrillation Failure
Efimov, I. R., Cheng, Y., Van Wagoner, D. R., Mazgalev, T., & Tchou, P. J. (1998) · Circulation Research · doi:10.1161/01.res.82.8.918 · Cited by 290
Tissue Damage by Pulsed Electrical Stimulation
Butterwick, A., Vankov, A., Huie, P., Freyvert, Y., & Palanker, D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.908310 · Cited by 136
Metadata
- Authors
- Roth, B. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1995
- Volume
- 42
- Issue
- 12
- Pages
- 1174-1184
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2083432549
- Cited by
- 184
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.