A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We have investigated the relative performance of an adaptive and nonadaptive 60-Hz notch filter applied to an ECG signal. We evaluated the performance of the two implementations with respect to adaptation rate (or transient response time), signal distortion, and implementation complexity. We also investigated the relative effect of adaptive and nonadaptive 60-Hz filtering on ECG data compression. With a 360 Hz sample rate and an adaptation time of approximately 0.3 s for a 1 mV 60-Hz signal, the adaptive implementation is less complex and introduces less noise, particularly in the ST-segment, into a typical ECG signal. When applied to ECG signals, prior to data compression by average beat subtraction and residual differencing, the residual signal resulting from the adaptively filtered signal had an average entropy 0.37 bits per sample (bps) lower than the unfiltered signal. The nonadaptive 60-Hz filter produced an average entropy decrease of 0.08 bps relative to the unfiltered ECG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
Digital Signal Processing: Principles, Algorithms, and Applications
Proakis, J. G., & Manolakis, D. G. (1992) · Cited by 4,601
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
60-Hz Interference in Electrocardiography
Huhta, J. C., & Webster, J. G. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324169 · Cited by 412
Digital Filters for Real-Time ECG Signal Processing Using Microprocessors
Ahlstrom, M. L., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325589 · Cited by 189 · cited 1×
“Ahlstrom and Tompkins [ 4 ] reported on an adaptive 60-HZ filter for ECG signals that used an internally generated reference signal.”
Background
Cited by
A nonlinear adaptive method of elimination of power line interference in ECG signals
Ziarani, A. K., & Konrad, A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1001968 · Cited by 241
“is reported to present serious practical difficulties and is nearly impossible to implement [8].”
BackgroundElectrocardiogram signals de-noising using lifting-based discrete wavelet transform
Erçelebi, E. (2004) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(03)00090-8 · Cited by 161
Fractal and EMD based removal of baseline wander and powerline interference from ECG signals
Agrawal, S., & Gupta, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.07.030 · Cited by 102
Metadata
- Authors
- Hamilton, P. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1996
- Volume
- 43
- Issue
- 1
- Pages
- 105-109
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2095970328
- Cited by
- 171
- References
- 5
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG. https://app.cochat.ai/papers/10.1109/10.477707
- The paper
- Hamilton, P. S. (1996). A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.477707
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.