The DOI matches its Crossref record.
Electrical conductivity values used with the bidomain model of cardiac tissue
Abstract
Electrical conductivities in the bidomain model of cardiac tissue are expressed as functions of four parameters. These expressions allow simulations to be performed using nominal, equal, and reciprocal anisotropy without introducing undesired effects, such as length constant variations. Relative values of the bidomain conductivities are estimated to be: sigma iL = 1, sigma iT = 0.1, sigma eL = 1, and sigma eT = 0.4.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Potse, M., Dube, B., Richer, J., Vinet, A., & Gulrajani, R. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880875 · Cited by 470
Petrini, G., Moreva, E., Bernardi, E., Traina, P., Tomagra, G., Carabelli, V., Degiovanni, I. P., & Genovese, M. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000066 · Cited by 63
In vivo ephaptic coupling allows memory network formation
Pinotsis, D. A., & Miller, E. K. (2023) · Cerebral Cortex · doi:10.1093/cercor/bhad251 · Cited by 62
Beyond dimension reduction: stable electric fields emerge from and allow representational drift
Pinotsis, D. A., & Miller, E. K. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119058 · Cited by 37
Metadata
- Authors
- Roth, B. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997-04
- Volume
- 44
- Issue
- 4
- Pages
- 326-328
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2112771147
- Cited by
- 208
- References
- 0
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical conductivity values used with the bidomain model of cardiac tissue. https://app.cochat.ai/papers/10.1109/10.563303
- The paper
- Roth, B. J. (1997). Electrical conductivity values used with the bidomain model of cardiac tissue. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.563303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.