Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filters

Disselhorst-Klug, C., Silny, J., Rau, G.·1997·IEEE Transactions on Biomedical Engineering

Abstract

The conventional bipolar surface electromyography (EMG) technique detects, due to its low spatial resolution, the superimposed electromyographic activity of a large number of motor units (MU's). In superficial muscles the isolated action potentials of the most superficial MU's can be recorded noninvasively by means of surface electrodes, if the method of spatial filtering, in connection with electrode arrays, is used. Up to now, only filters with an anisotropic transfer function have been used. As the surface potential distribution generated by the excitation of the MU's contains spatial frequencies in the anisotropic range of those filters, it can be assumed that isotropic spatial filters detect the single MU activity more effectively. In the present study, different isotropic and anisotropic filters have been compared by means of theoretical field simulations and experiments in volunteers. A tripole model for an excited MU was used as the basis for simulating the spatial extension of the filter response for each of the investigated filters. The spatial extension is an indicative of the spatial resolution. For the experimental validation, the total number of single motor units was not directly investigated, but the signal-to-noise ratio (SNR) has been determined. Therefore, the potential distribution generated on the skin surface during maximum voluntary contraction has been simultaneous spatially filtered with each of the investigated filters. The simulations show that an isotropic spatial filtering procedure reduces the spatial extension of the filter response and improves the spatial resolution of the EMG-recording arrangement in comparison to anisotropic spatial filters up to 30%. In other words, the spatial selectivity of the arrangement is increased. This improvement in the filter performance is more pronounced for MU's located close to the skin surface than for MU's more distantly located. Additionally, this theoretical improvement in selectivity depends on the direction of the excitation spread relative to the filter alignment. However, the investigations also show that isotropic filters offer an advantage, compared to anisotropic filters, only when the investigated MU is located extremely close to the filter input. The results of the simulations can be confirmed by the experimental investigations. An improvement of 11% in the SNR, relative to anisotropic spatial filters, can be established when using an isotropic spatial filter. This experimental improvement in selectivity is less than the theoretical improvement because the experimentally investigated MU's have less portion in the anisotropic range of the filters than the simulated one at best.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.594897

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Disselhorst-Klug, C., Silny, J., & Rau, G.
Venue
IEEE Transactions on Biomedical Engineering
Published
1997-07
Volume
44
Issue
7
Pages
567-574
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2122585109
Cited by
172
References
0
FWCI
1.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filters. https://app.cochat.ai/papers/10.1109/10.594897
The paper
Disselhorst-Klug, C., Silny, J., & Rau, G. (1997). Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filters. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.594897

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.