The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait
Abstract
The aim of this work is to present an original double-threshold detector of muscle activation, specifically developed for gait analysis. This detector operates on the raw myoelectric signal and, hence, it does not require any envelope detection. Its performances are fixed by the values of three parameters, namely, false-alarm probability (Pfa), detection probability, and time resolution. Double-threshold detectors are preferable to single-threshold ones because, for a fixed value of the Pfa, they yield higher detection probability; furthermore, they allow the user to select the couple false alarm-detection probability with a higher degree of freedom, thus, adapting the performances of the detector to the characteristics of the myoelectric signal of interest and of the experimental situation. In this paper, first we derive the detection algorithm and describe different strategies for selecting its parameters, then we present the performances of the proposed procedure evaluated by means of computer simulations, and finally we report an example of application to myoelectric signals recorded during gait. The characterization of the proposed double-threshold detector demonstrates that, in most practical situations, the bias of the estimates of the on-off transitions is smaller than 10 ms, the standard deviation may be kept lower than 15 ms, and the percentage of erroneous patterns is below 5%. These results show that this detection approach is satisfactory in research applications as well as in the clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
Numerical Recipes, The Art of Scientific Computing
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., & Gould, H. (1987) · American Journal of Physics · doi:10.1119/1.14981 · Cited by 10,024
Spectral Analysis and its Applications.
Freiberger, W. F., Jenkins, G. M., & Watts, D. G. (1969) · Journal of the American Statistical Association · doi:10.2307/2286100 · Cited by 4,981
Random variables and stochastic processes
Larson, H. J., & Shubert, B. O. (1979) · Wiley eBooks · Cited by 4,640
The development of mature gait.
Sutherland, D. H., Olshen, R., Cooper, L., & Woo, S. L. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062030-00004 · Cited by 840
Numerical Recipes, The Art of Scientific Computing.
Shampine, L. F., Press, W. H., Flannery, B. P., Teukolsky, S. A., & Vetterling, W. T. V. (1987) · The American Mathematical Monthly · doi:10.2307/2322833 · Cited by 808
The influence of total knee-replacement design on walking and stair-climbing.
Andriacchi, T. P., Galante, J. O., & Fermier, R. W. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264090-00008 · Cited by 642
Frequency Parameters of the Myoelectric Signal as a Measure of Muscle Conduction Velocity
Stulen, F. B., & De Luca, C. J. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324738 · Cited by 576
The development of mature gait
Sutherland, D. (1997) · Gait & Posture · doi:10.1016/s0966-6362(97)00029-5 · Cited by 351
The Development of mature walking
Sutherland, D. H. (1988) · Medical Entomology and Zoology · Cited by 276
The Development of Mature Walking
McKinley, I. (1989) · Archives of Disease in Childhood · doi:10.1136/adc.64.7.1099 · Cited by 268
Advanced Digital Signal Processing
Proakis, J. G., Ling, F., & Rader, C. M. (1992) · Cited by 248
Gait Analysis of the Triceps Surae in Cerebral Palsy
Perry, J., Hoffer, M. M., GIOVAN, P., Antonelli, D. J., & GREENBERG, R. (1974) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197456030-00008 · Cited by 148
Pathologic gait diagnosis with computer-averaged electromyographic profiles.
Winter, D. A. (1984) · PubMed · Cited by 103
The Development of Mature Walking
Biden, E. (1991) · Cited by 95
Pattern recognition of multiple EMG signals applied to the description of human gait
Bekey, G. A., Chang, C.-W., Perry, J., & Hoffer, M. M. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10546 · Cited by 53
Perry, J., Hoffer, M. M., Antonelli, D. J., Plut, J., LEWIS, G. E., & Greenberg, R. (1976) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197658020-00007 · Cited by 48
Representing and clustering electromyographic gait patterns with multivariate techniques
Shiavi, R., & Griffin, P. P. (1981) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442775 · Cited by 42
Muscle Fatigue Monitor (MFM): Second Generation
Gilmore, L. D., & Luca, C. J. D. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325634 · Cited by 39
Shiavi, R., Bourne, J., & Holland, A. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325841 · Cited by 28
Changes in Electromyographic Gait Patterns of Calf Muscles with Walking Speed
Shiavi, R., & Griffin, P. P. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325171 · Cited by 21
Cited by
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Surface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Metadata
- Authors
- Bonato, P., D'Alessio, T., & Knaflitz, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1998-03
- Volume
- 45
- Issue
- 3
- Pages
- 287-299
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2136908787
- Cited by
- 375
- References
- 21
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.