Cited by 63Neuroscience and Neural EngineeringTactile and Sensory InteractionsMuscle activation and electromyography studies

Information contained in sensory nerve recordings made with intrafascicular electrodes

Goodall, E.V., Lefurge, T.M., Horch, K.W.·1991·IEEE Transactions on Biomedical Engineering

Abstract

Multiunit recordings were made in anesthetized cats with chronically implanted intrafascicular electrodes over a period of six months. Neural signals recorded with these electrodes consisted of activity in sensory fibers innervating a variety of cutaneous mechanoreceptors. Mechanical stimuli were used to selectively activate individual nerve fibers, and the receptive field and receptor type were identified for each unit. Over a period of six months, there was a net shift in the recorded population, but the electrodes continued to provide a representative sample of the activity in the fascicle as a whole. The total number of units from which activity could be recorded remained roughly constant with time, and individual units persisted in the recordings for up to six months. These results indicate that intrafascicular electrodes could be used to sample information carried by individual somatosensory fibers on a long term basis.

Integrity signals

Registry

Crossref · 10.1109/10.83604

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The first Pt-Ir LIFEs were stiff, causing relative motion within the fascicle, gradual drift of the recorded nerve fiber population, and reduction in signal quality.

    “The first Pt-Ir LIFEs were quite stiff, which resulted in a relative motion of the electrode within the fascicle. This in turn resulted in a gradual drift of the recorded nerve fiber population and a reduction in signal quality (Goodall et al., 1991).”

    From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Goodall et al., 1991

The citation lists haven’t been fetched yet

References 9 · Cited by 63

Authors
Goodall, E. V., Lefurge, T. M., & Horch, K. W.
Affiliations
University of Utah (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1991
Volume
38
Issue
9
Pages
846-850
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2141190300
Cited by
63
References
9
Citations by year
2025: 2 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 1 · 2015: 2 · 2013: 3 · 2012: 4
FWCI
0.90
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
intrafascicular electrodes, multi-unit recording, sensory nerve fibers, cutaneous mechanoreceptors, receptive fields, long-term neural recording, chronic implantation
MeSH terms
Animals, Cats, Electric Stimulation, Electrodes, Implanted, Peripheral Nerves, Radial Nerve, Sensory Receptor Cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review