A 122-channel whole-cortex SQUID system for measuring the brain's magnetic fields
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A 122-channel neuromagnetometer with a helmet-shaped detector array covering the entire head allows simultaneous recording of magnetic fields over the whole cortex. The instrument has 122 planar first-order gradiometers in dual units at 61 measurement sites. The SQUIDs are directly coupled to the read-out electronics, with amplifier noise cancellation to eliminate the need for separate preamplifiers inside the magnetically shielded room. The authors analyze the performance of the device and compare it with traditional axial gradiometer arrays by considering signal-to-noise ratios, spatial sampling theory, confidence intervals for equivalent current dipole fits, and information-theoretical channel capacity. The analysis includes the fact that instrument noise is smaller than the background activity of the brain; the signal-to-noise ratio and the resolution of the planar array are in that case equal to or better than that of an axial array. The number of channels and their spacing are very suitable for neuromagnetic measurements.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Self-citation
Cited by
Language-specific phoneme representations revealed by electric and magnetic brain responses
Näätänen, R., Lehtokoski, A., Lennes, M., Cheour, M., Huotilainen, M., Iivonen, A., Vainio, M., Alku, P., Ilmoniemi, R. J., Luuk, A., et al. (1997) · Nature · doi:10.1038/385432a0 · Cited by 1,260
Long-Range Temporal Correlations and Scaling Behavior in Human Brain Oscillations
Linkenkaer-Hansen, K., Nikouline, V. V., Palva, J. M., & Ilmoniemi, R. J. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-04-01370.2001 · Cited by 1,149
“Spontaneous brain activity from 10 normal subjects (aged 20–30 years, one female) was recorded simultaneously with magnetoencephalography (MEG) and EEG using a whole-scalp magnetometer array containing 122 planar gradiometers (Knuutila et al., 1993) and a 64-channel EEG cap (Virtanen et al., 1996).”
MethodSignal-space projection method for separating MEG or EEG into components
Uusitalo, M. A., & Ilmoniemi, R. J. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534144 · Cited by 913
Signal Processing in Magnetoencephalography
Vrba, J., & Robinson, S. E. (2001) · Methods · doi:10.1006/meth.2001.1238 · Cited by 716
Liu, A. K., Belliveau, J. W., & Dale, A. M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.15.8945 · Cited by 384
Metadata
- Authors
- Knuutila, J. E. T., Ahonen, A. I., Hamalainen, M. S., Kajola, M. J., Laine, P. P., Lounasmaa, O. V., Parkkonen, L. T., Simola, J. T. A., & Tesche, C. D.
- Venue
- IEEE Transactions on Magnetics
- Published
- 1993-11
- Volume
- 29
- Issue
- 6
- Pages
- 3315-3320
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2111793084
- Cited by
- 96
- References
- 1
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 122-channel whole-cortex SQUID system for measuring the brain's magnetic fields. https://app.cochat.ai/papers/10.1109/20.281163
- The paper
- Knuutila, J. E. T., Ahonen, A. I., Hamalainen, M. S., Kajola, M. J., Laine, P. P., Lounasmaa, O. V., Parkkonen, L. T., Simola, J. T. A., & Tesche, C. D. (1993). A 122-channel whole-cortex SQUID system for measuring the brain's magnetic fields. IEEE Transactions on Magnetics. https://doi.org/10.1109/20.281163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.