The DOI matches its Crossref record.
Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging
Abstract
Quantitative imaging of the human thorax poses one of the most difficult challenges for three-dimensional (3-D) (septaless) positron emission tomography (PET), due to the strong attenuation of the annihilation radiation and the large contribution of scattered photons to the data. In [/sup 18/F] fluorodeoxyglucose (FDG) studies of the heart with the patient's arms in the field of view, the contribution of scattered events can exceed 50% of the total detected coincidences. Accurate correction for this scatter component is necessary for meaningful quantitative image analysis and tracer kinetic modeling. For this reason, the authors have implemented a single-scatter simulation technique for scatter correction in positron volume imaging. Here, they describe this algorithm and present scatter correction results from human and chest phantom studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Imaging brain amyloid in Alzheimer's disease with Pittsburgh Compound‐B
Klunk, W. E., Engler, H., Nordberg, A., Wang, Y., Blomqvist, G., Holt, D. P., Bergström, M., Savitcheva, I., Huang, G., Estrada, S., et al. (2004) · Annals of Neurology · doi:10.1002/ana.20009 · Cited by 4,496
New, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Self-citationQuantification of myocardial blood flow with 82Rb dynamic PET imaging
Lortie, M., Beanlands, R. S. B., Yoshinaga, K., Klein, R., DaSilva, J. N., & deKemp, R. A. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0478-2 · Cited by 451
Self-citationA Single Scatter Simulation Technique for Scatter Correction in 3D PET
Watson, C. C., Newport, D., & Casey, M. E. (1996) · Computational Imaging and Vision · doi:10.1007/978-94-015-8749-5_18 · Cited by 333
Self-citationRelevance of accurate Monte Carlo modeling in nuclear medical imaging
Zaidi, H. (1999) · Medical Physics · doi:10.1118/1.598559 · Cited by 279
Metadata
- Authors
- Watson, C. C., Newport, D., Casey, M. E., deKemp, R. A., Beanlands, R. S., & Schmand, M.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1997-02
- Volume
- 44
- Issue
- 1
- Pages
- 90-97
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W1594154392
- Cited by
- 218
- References
- 0
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging. https://app.cochat.ai/papers/10.1109/23.554831
- The paper
- Watson, C. C., Newport, D., Casey, M. E., deKemp, R. A., Beanlands, R. S., & Schmand, M. (1997). Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.554831
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.