The DOI matches its Crossref record.
Fast reconstruction of 3D PET data with accurate statistical modeling
Abstract
This paper presents the results of combining high sensitivity 3D PET whole-body acquisition followed by fast 2D iterative reconstruction methods based on accurate statistical models. This combination is made possible by Fourier rebinning (FORE), which accurately converts a 3D data set to a set of 2D sinograms. The combination of volume imaging with statistical reconstruction allows improvement of noise-bias trade-offs when image quality is dominated by measurement statistics. The rebinning of the acquired data into a 2D data set reduces the computation time of the reconstruction. For both penalized weighted least squares (PWLS) and ordered-subset EM (OSEM) reconstruction methods, the usefulness of a realistic model of the expected measurement statistics is shown when the data are pre-corrected for attenuation and random and scattered coincidences, as required for the FORE rebinning algorithm. The results presented are based on 3D simulations of whole body scans that include the major statistical effects of PET acquisition and data correction procedures. As the PWLS method requires knowledge of the variance of the projection data, a simple model for the effect of FORE rebinning on data variance is developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Self-citationPhysical and clinical performance of the mCT time-of-flight PET/CT scanner
Jakoby, B. W., Bercier, Y., Conti, M., Casey, M. E., Bendriem, B., & Townsend, D. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/8/004 · Cited by 492
Self-citationIterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
History and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
Self-citationMultimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Self-citation
Metadata
- Authors
- Comtat, C., Kinahan, P. E., Defrise, M., Michel, C., & Townsend, D. W.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1998-06
- Volume
- 45
- Issue
- 3
- Pages
- 1083-1089
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2105168883
- Cited by
- 165
- References
- 0
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast reconstruction of 3D PET data with accurate statistical modeling. https://app.cochat.ai/papers/10.1109/23.681983
- The paper
- Comtat, C., Kinahan, P. E., Defrise, M., Michel, C., & Townsend, D. W. (1998). Fast reconstruction of 3D PET data with accurate statistical modeling. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.681983
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.