Silicon detectors with 3-D electrode arrays: fabrication and initial test results
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The first three-dimensional detectors with n and p electrodes that penetrate through the silicon substrate have been fabricated. Some expected properties, including low depletion voltages, wide voltage plateaus before leakage current limits are reached, and rapid charge collection are reviewed. Fabrication steps and initial test results for leakage currents and infrared signal detection are covered. The authors conclude with a description of current work, including fabrication of active-edge detectors, ones with sensitive areas that should extend to their physical edge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Currents Induced by Electron Motion
Ramo, S. (1939) · Proceedings of the IRE · doi:10.1109/jrproc.1939.228757 · Cited by 1,561
Currents to Conductors Induced by a Moving Point Charge
Shockley, W. (1938) · Journal of Applied Physics · doi:10.1063/1.1710367 · Cited by 1,300 · cited 1×
“The calculations for the 3-D arrangement use the two-dimensional (2-D) finite element program, MEDICI [15], which also handles such aspects of charge motion as drift, diffusion, and Ramo’s theorem effects [16], [17].”
Method
Metadata
- Authors
- Kenney, C., Parker, S., Segal, J., & Storment, C.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1999-08
- Volume
- 46
- Issue
- 4
- Pages
- 1224-1236
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2167473906
- Cited by
- 182
- References
- 2
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.