The DOI matches its Crossref record.
Asymmetrical duty cycle permits zero switching loss in PWM circuits with no conduction loss penalty
Abstract
It is shown that operating a bridge-type PWM switch mode power converter with asymmetrical duty ratios can eliminate switching losses with no increase in conduction loss. This circuit topology combines the best features of resonant (zero switching loss) and switch mode (low conduction loss) circuits. Design equations for the circuit are presented.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Single phase power factor correction: a survey
Garcia, O., Cobos, J. A., Prieto, R., Alou, P., & Uceda, J. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810856 · Cited by 662
Soft-switched DC/DC converter with PWM control
Oruganti, R., Heng, P. C., Guan, J. T. K., & Choy, L. A. (1998) · IEEE Transactions on Power Electronics · doi:10.1109/63.654964 · Cited by 79
Xu, X., Khambadkone, A. M., & Oruganti, R. (2007) · IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2007.4460246 · Cited by 18
Metadata
- Authors
- Imbertson, P., & Mohan, N.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1993
- Volume
- 29
- Issue
- 1
- Pages
- 121-125
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2123082907
- Cited by
- 233
- References
- 0
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Asymmetrical duty cycle permits zero switching loss in PWM circuits with no conduction loss penalty. https://app.cochat.ai/papers/10.1109/28.195897
- The paper
- Imbertson, P., & Mohan, N. (1993). Asymmetrical duty cycle permits zero switching loss in PWM circuits with no conduction loss penalty. IEEE Transactions on Industry Applications. https://doi.org/10.1109/28.195897
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.