The DOI matches its Crossref record.
Neural networks aided on-line diagnostics of induction motor rotor faults
Open accessAbstract
An improvement of induction-machine rotor fault diagnosis based on a neural network approach is presented. A neural network can replace in a more effective way the faulted machine models used to formalize the knowledge base of the diagnostic system with suitably chosen inputs and outputs. Training the neural network by data obtained from experimental tests on healthy machines and from simulation in the case of faulted machines, the diagnostic system can discern between healthy and faulty machines. This procedure replaces the formulation of a trigger threshold, required in the diagnostic procedure based on the machine models. >
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Lee, J., Wu, F., Zhao, W., Ghaffari, M., Liao, L., & Siegel, D. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2013.06.004 · Cited by 1,594
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Self-citationA Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Recent developments of induction motor drives fault diagnosis using AI techniques
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873207 · Cited by 511
Self-citationA comprehensive review for industrial applicability of artificial neural networks
Meireles, M. R. G., Almeida, P. E. M., & Simoes, M. G. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.812470 · Cited by 482
AI techniques in induction machines diagnosis including the speed ripple effect
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.658729 · Cited by 442
Self-citationYazici, B., & Kliman, G. B. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.753640 · Cited by 266
da Silva, A. M., Povinelli, R. J., & Demerdash, N. A. O. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.909060 · Cited by 266
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345492 · Cited by 264
Frosini, L., & Bassi, E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026770 · Cited by 254
Metadata
- Authors
- Filippetti, F., Franceschini, G., & Tassoni, C.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1995
- Volume
- 31
- Issue
- 4
- Pages
- 892-899
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2166361139
- Cited by
- 216
- References
- 0
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.