An actively cooled 120 kW coaxial winding transformer for fast charging electric vehicles
The DOI matches its Crossref record.
Abstract
A 120 kW coaxial winding transformer has been built and tested to verify previous indications that a high power transformer is feasible with the key attributes of this novel design, namely: low leakage inductance, minimal effect of leakage field on core losses, low copper losses, and a convenient "nesting" structure well suited for separability of the findings. The power transfer capability is more than double that of any previously published result for coaxial winding transformers. The application chosen for the fabricated transformer was an inductive coupler for fast charging of electric vehicles. Presented are the key parametric decisions, their impact on transformer fabrication and characteristics, and the results of these design choices as observed in the experimental data. The final design has active cooling to facilitate high power density and a separable core to allow the primary and secondary windings to be coupled and uncoupled. The experimental data shows performance better than expected, with a magnetizing to leakage inductance ratio of 1000:1, efficiency well over 99% and power density of 25 kW/kg.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development of a Single-Sided Flux Magnetic Coupler for Electric Vehicle IPT Charging Systems
Budhia, M., Boys, J. T., Covic, G. A., & Huang, C.-Y. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2179274 · Cited by 1,273
Modern Trends in Inductive Power Transfer for Transportation Applications
Covic, G. A., & Boys, J. T. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2264473 · Cited by 1,263
Covic, G. A., & Boys, J. T. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2244536 · Cited by 1,223
Design and Optimization of Circular Magnetic Structures for Lumped Inductive Power Transfer Systems
Budhia, M., Covic, G. A., & Boys, J. T. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143730 · Cited by 1,039
An actively cooled high power, high frequency transformer with high insulation capability
Heinemann, L. (2003) · APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335) · doi:10.1109/apec.2002.989270 · Cited by 135
Huang, P., Mao, C., Wang, D., Wang, L., Duan, Y., Qiu, J., Xu, G., & Cai, H. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674591 · Cited by 78
Metadata
- Authors
- Klontz, K. W., Divan, D. M., & Novotny, D. W.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1995
- Volume
- 31
- Issue
- 6
- Pages
- 1257-1263
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2116098936
- Cited by
- 58
- References
- 0
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.