Dielectrophoretic separation of cancer cells from blood
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Recent measurements have demonstrated that the dielectric properties of cells depend on their type and physiological status. For example, MDA-231 human breast cancer cells were found to have a mean plasma membrane specific capacitance of 26 mF/m(2), more than double the value (11 mF/m(2)) observed for resting T-lymphocytes. When an inhomogeneous ac electric field is applied to a particle, a dielectrophoretic (DEP) force arises that depends on the particle dielectric properties. Therefore, cells having different dielectric characteristics will experience differential DEP forces when subjected to such a field. In this article, we demonstrate the use of differential DEP forces for the separation of several different cancerous cell types from blood in a dielectric affinity column. These separations were accomplished using thin, flat chambers having microelectrode arrays on the bottom wall. DEP forces generated by the application of ac fields to the electrodes were used to influence the rate of elution of cells from the chamber by hydrodynamic forces within a parabolic fluid flow profile. Electrorotation measurements were first made on the various cell types found within cell mixtures to be separated, and theoretical modeling was used to derive the cell dielectric parameters. Optimum separation conditions were then predicted from the frequency and suspension conductivity dependencies of cell DEP responses defined by these parameters. Cell separations were then undertaken for various ratios of cancerous to normal cells at different concentrations. Eluted cells were characterized in terms of separation efficiency, cell viability, and separation speed. For example, 100% efficiency was achieved for purging MDA-231 cells from blood at the tumor to normal cell ratio 1:1 x 10(5) or 1:3 x 10(5), cell viability was not compromised, and separation rates were at least 10(3) cells/s. Theoretical and experimental criteria for the design and operation of such separators are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Self-citationLong-term human breast carcinoma cell lines of metastatic origin: Preliminary characterization
Cailleau, R., Olivé, M., & Cruciger, Q. V. J. (1978) · In Vitro · doi:10.1007/bf02616120 · Cited by 679
Separation of Blood Leucocytes, Granulocytes and Lymphocytes
Bøyum, A. (1974) · Tissue Antigens · doi:10.1111/j.1399-0039.1974.tb00252.x · Cited by 663
Borek, F. (1989) · Journal of Immunological Methods · doi:10.1016/0022-1759(89)90304-9 · Cited by 365
Dielectrophoretic characterization and separation of micro-organisms
Markx, G. H., Huang, Y., Zhou, X. F., & Pethig, R. (1994) · Microbiology · doi:10.1099/00221287-140-3-585 · Cited by 237
Self-citationSelective dielectrophoretic confinement of bioparticles in potential energy wells
Wang, X. B., Huang, Y., Burt, J. P. H., Markx, G. H., & Pethig, R. (1993) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/26/8/019 · Cited by 223
Self-citationWang, X.-B., Huang, Y., Gascoyne, P. R. C., Becker, F. F., Hölzel, R., & Pethig, R. (1994) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(94)90170-8 · Cited by 193
Self-citationZhang, R., Fidler, I. J., & Price, J. E. (1991) · PubMed · Cited by 171
Hypotonically induced changes in the plasma membrane of cultured mammalian cells
Sukhorukov, V. L., Arnold, W. M., & Zimmermann, U. (1993) · The Journal of Membrane Biology · doi:10.1007/bf00233049 · Cited by 108
Dielectric properties of yeast cells as determined by electrorotation
Hölzel, R., & Lamprecht, I. (1992) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(92)90150-k · Cited by 97
Macrophage activation by T cells: cognate and non-cognate signals
Stout, R. D. (1993) · Current Opinion in Immunology · doi:10.1016/0952-7915(93)90059-2 · Cited by 91
Rotation of an isolated cell in a rotating electric field
Arnold, W. M., & Zimmermann, U. (1982) · Die Naturwissenschaften · doi:10.1007/bf00396446 · Cited by 55
Isolation of human peripheral blood monocytes: A comparative methodological study
Gadeberg, O., Rhodes, J. M., & Larsen, S. O. (1979) · Journal of Immunological Methods · doi:10.1016/0022-1759(79)90280-1 · Cited by 21
Eggleton, P., Fisher, D., & Crawford, N. (1992) · Journal of Leukocyte Biology · doi:10.1002/jlb.51.6.617 · Cited by 20
THE USE OF MONOCLONAL ANTIBODIES IN ALLOGENEIC BONE MARROW TRANSPLANTATION
Fischer, A. (1993) · British Journal of Haematology · doi:10.1111/j.1365-2141.1993.tb04686.x · Cited by 12
Particle dipole-dipole interaction in AC electric fields [cellular application]
Wang, X.-B., Huang, Y., Gascoyne, P. R. C., & Becker, F. F. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1994.415286 · Cited by 4
Self-citation
Cited by
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Self-citationParticle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Isolation of rare cells from cell mixtures by dielectrophoresis
Gascoyne, P. R. C., Noshari, J., Anderson, T. J., & Becker, F. F. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800373 · Cited by 436
Self-citationDielectrophoresis in microfluidics technology
Çetin, B., & Li, D. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100167 · Cited by 411
The dielectric properties of biological cells at radiofrequencies: applications in biotechnology
Markx, G. H., & Davey, C. L. (1999) · Enzyme and Microbial Technology · doi:10.1016/s0141-0229(99)00008-3 · Cited by 333
Metadata
- Authors
- Gascoyne, P. R. C., Wang, X.-B., Huang, Y., & Becker, F. F.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1997-05
- Volume
- 33
- Issue
- 3
- Pages
- 670-678
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W1993260486
- Cited by
- 406
- References
- 18
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.