The DOI matches its Crossref record.
Waveform compensation of PWM inverter with cyclic fluctuating loads
Abstract
A repetitive voltage compensation technique that generates a high-quality sinusoidal output voltage from a single-phase pulse width modulation (PWM) inverter used for uninterruptible power supplies is described. A repetitive control technique eliminates the steady-state error in the distorted output voltage caused by cyclic loads. The proposed PWM inverter system uses microprocessor-based closed-loop digital feedback with a sinusoidal reference. The PWM pattern is determined at every sampling instant by the proposed algorithm, implemented by a microprocessor using a set of detected output voltages and the reference signals through one cycle. The system has low distortion and very fast response for AC phase-controlled loads.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control topology options for single-phase UPS inverters
Ryan, M. J., Brumsickle, W. E., & Lorenz, R. D. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568015 · Cited by 429
Direct repetitive control of SPWM inverter for UPS purpose
Zhang, K., Kang, Y., Xiong, J., & Chen, J. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810846 · Cited by 396
Control of Distributed Generation Systems— Part I: Voltages and Currents Control
Marwali, M. N., & Keyhani, A. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836685 · Cited by 329
Tzou, Y.-Y., Ou, R.-S., Jung, S.-L., & Chang, M.-Y. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.602567 · Cited by 284
Repetitive Compensation of Fluctuating DC Link Voltage for Railway Traction Drives
Ouyang, H., Zhang, K., Zhang, P., Kang, Y., & Xiong, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2105283 · Cited by 83
Metadata
- Authors
- Haneyoshi, T., Kawamura, A., & Hoft, R. G.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1988
- Volume
- 24
- Issue
- 4
- Pages
- 582-589
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2109263292
- Cited by
- 231
- References
- 0
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.