A power line conditioner using cascade multilevel inverters for distribution systems
Abstract
In this paper, a power line conditioner using a cascade multilevel inverter is presented for voltage regulation, reactive power (VAr) compensation, and harmonic filtering. The cascade M-level inverter consists of (M-1)/2 H bridges, in which each bridge has its own separate DC source. This new inverter can: (1) generate almost sinusoidal waveform voltage with only one time switching per line cycle; (2) eliminate transformers of multipulse inverters used in the conventional static VAr compensators; and (3) make possible direct connection to the 13.8 kV power distribution system in parallel and series without any transformer. In other words, the power line conditioner is much more efficient and more suitable to VAr compensation and harmonic filtering of distribution systems than traditional multipulse and pulsewidth modulation inverters. It has been shown that the new inverter is especially suited for VAr compensation. This paper focuses on feasibility and control schemes of the cascade inverter for voltage regulation and harmonic filtering in distribution systems. Analytical, simulated, and experimental results show the superiority of the new power line conditioner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Abu-Rub, H., Holtz, J., Rodriguez, J., & Baoming, G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043039 · Cited by 1,337
Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042
Kesler, M., & Ozdemir, E. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2100330 · Cited by 311
Metadata
- Authors
- Peng, F. Z., McKeever, J. W., & Adams, D. J.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1998
- Volume
- 34
- Issue
- 6
- Pages
- 1293-1298
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W4253367313
- Cited by
- 246
- References
- 0
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A power line conditioner using cascade multilevel inverters for distribution systems. https://app.cochat.ai/papers/10.1109/28.739012
- The paper
- Peng, F. Z., McKeever, J. W., & Adams, D. J. (1998). A power line conditioner using cascade multilevel inverters for distribution systems. IEEE Transactions on Industry Applications. https://doi.org/10.1109/28.739012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.