The DOI matches its Crossref record.
Failure identification and analysis for high-voltage induction motors in the petrochemical industry
Abstract
This paper gives a synopsis of condition monitoring methods, both as a diagnostic tool and as a technique for failure identification in high-voltage induction motors in industry. New operating experience data for 483 motor units consisting of 6135 unit years are registered and processed statistically to ascertain the connection between motor data, protection and condition monitoring methods, maintenance philosophy and different types of failures. The different types of failures are further analyzed to determine the failure initiators, contributors and underlying causes. The results have been compared with those of a previous survey, the "IEEE Report of Large Motor Reliability Survey of Industrial and Commercial Installations, 1985." In the present survey, the motors range from 100 to 1300 kW; 47% of them are between 100-500 kW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Residual-life distributions from component degradation signals: A Bayesian approach
GEBRAEEL, N. Z., LAWLEY, M. A., LI, R., & RYAN, J. K. (2005) · IIE Transactions · doi:10.1080/07408170590929018 · Cited by 788
Bearing fault diagnosis base on multi-scale CNN and LSTM model
Chen, X., Zhang, B., & Gao, D. (2021) · Journal of Intelligent Manufacturing · doi:10.1007/s10845-020-01600-2 · Cited by 739
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
A Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Condition Monitoring and Fault Diagnosis of Induction Motors: A Review
Choudhary, A., Goyal, D., Shimi, S. L., & Akula, A. (2019) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-018-9286-z · Cited by 302
A Survey of Methods for Detection of Stator-Related Faults in Induction Machines
Tallam, R. M., Lee, S. B., Stone, G. C., Kliman, G. B., Yoo, J., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900448 · Cited by 301
Hasan, M. J., & Kim, J.-M. (2018) · Applied Sciences · doi:10.3390/app8122357 · Cited by 105
“Bearings play an important role in condition monitoring because, in more than 50% of the cases involving induction motor failures, they are the root cause of the failure [2,8].”
Background
Metadata
- Authors
- Thorsen, O. V., & Dalva, M.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1999
- Volume
- 35
- Issue
- 4
- Pages
- 810-818
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2140055317
- Cited by
- 228
- References
- 0
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.