The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Stator winding fault diagnosis in three-phase synchronous and asynchronous motors, by the extended Park's vector approach
Abstract
This paper describes the use of the extended Park's vector approach (EPVA) for diagnosing the occurrence of stator winding faults in operating three-phase synchronous and asynchronous motors. The major theoretical principles related with the EPVA are presented and it is shown how stator winding faults can be effectively diagnosed by the use of this noninvasive approach. Experimental results, obtained in the laboratory, corroborate that these faults can be detected, in the EPVA signature, by the identification of a spectral component at twice the fundamental supply frequency. Onsite tests, conducted in a power generation plant and in a cement mill, demonstrate the effectiveness of the EPVA in the detection of these faults in large industrial motors, rated up to 5 MW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transient analysis of cage induction machines under stator, rotor bar and end ring faults
Toliyat, H. A., & Lipo, T. A. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.391888 · Cited by 489
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394
Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach
Marques Cardoso, A. J., Cruz, S. M. A., & Fonseca, D. S. B. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.790920 · Cited by 315
Self-citationA new approach to on-line turn fault detection in AC motors
Kliman, G. B., Premerlani, W. J., Koegl, R. A., & Hoeweler, D. (2002) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.557113 · Cited by 303
Monitoring of defects in induction motors through air-gap torque observation
Hsu, J. S. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464514 · Cited by 217
An on-line method to detect incipient failure of turn insulation in random-wound motors
Sottile, J., & Kohler, J. L. (1993) · IEEE Transactions on Energy Conversion · doi:10.1109/60.260992 · Cited by 112
Alternatives for assessing the electrical integrity of induction motors
Kohler, J. L., Sottile, J., & Trutt, F. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.158836 · Cited by 109
Monitoring generators and large motors
Tavner, P. J., Gaydon, B. G., & Ward, D. M. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0024 · Cited by 91
Cited by
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
Fault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Speed/position sensor fault tolerant control in adjustable speed drives – A review
Bourogaoui, M., Sethom, H. B. A., & Belkhodja, I. S. (2016) · ISA Transactions · doi:10.1016/j.isatra.2016.05.003 · Cited by 67
Fault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
Zhang, J., Zhan, W., & Ehsani, M. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2936225 · Cited by 64
Metadata
- Authors
- Cruz, S. M. A., & Cardoso, A. J. M.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2001
- Volume
- 37
- Issue
- 5
- Pages
- 1227-1233
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W4233898916
- Cited by
- 464
- References
- 8
- FWCI
- 9.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stator winding fault diagnosis in three-phase synchronous and asynchronous motors, by the extended Park's vector approach. https://app.cochat.ai/papers/10.1109/28.952496
- The paper
- Cruz, S. M. A., & Cardoso, A. J. M. (2001). Stator winding fault diagnosis in three-phase synchronous and asynchronous motors, by the extended Park's vector approach. IEEE Transactions on Industry Applications. https://doi.org/10.1109/28.952496
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.