The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Wide-span optical frequency comb generator for accurate optical frequency difference measurement
Abstract
An optical frequency comb (OFC) generator was realized for accurate optical frequency difference measurement of 1.5 mu m wavelength semiconductor lasers by using a high frequency LiNbO/sub 3/ electrooptic phase modulator which was installed in a Fabry-Perot cavity. It was confirmed that the span of the OFC was wider than 4 THz. By using semiconductor lasers whose spectrum linewidths were narrowed to 1 kHz and a sensitive optical balanced-mixer-receiver for measuring beat signal between the sideband of the comb and the laser, we demonstrated a frequency difference measurement up to 0.5 THz with a signal-to-noise ratio higher than 61 dB, and a heterodyne optical phase locking with a heterodyne frequency of 0.5 THz in which the residual phase error variance was less than 0.01 rad/sup 2/. The maximum measurable frequency difference, which was defined as the sideband frequency with the signal-to-noise ratio of 0 dB, was estimated to be 4 THz.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Telle, H. R., Meschede, D., & Hänsch, T. W. (1990) · Optics Letters · doi:10.1364/ol.15.000532 · Cited by 192
High-repetition-rate optical pulse generator using a Fabry-Perot electro-optic modulator
Kobayashi, T., SUETA, T., Cho, Y., & Matsuo, Y. (1972) · Applied Physics Letters · doi:10.1063/1.1654403 · Cited by 140
Homodyne optical phase locking of resonant cavity coupled semiconductor lasers
Shin, C., & Ohtsu, M. (1993) · IEEE Journal of Quantum Electronics · doi:10.1109/3.199292 · Cited by 13
Self-citation
Cited by
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Optical frequency comb generation from a monolithic microresonator
Del’Haye, P., Schliesser, A., Arcizet, O., Wilken, T., Holzwarth, R., & Kippenberg, T. J. (2007) · Nature · doi:10.1038/nature06401 · Cited by 2,290
Integrated photonics on thin-film lithium niobate
Zhu, D., Shao, L., Yu, M., Cheng, R., Desiatov, B., Xin, C. J., Hu, Y., Holzgrafe, J., Ghosh, S., Shams-Ansari, A., et al. (2021) · Advances in Optics and Photonics · doi:10.1364/aop.411024 · Cited by 1,516
Colloquium: Femtosecond optical frequency combs
Cundiff, S. T., & Ye, J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.325 · Cited by 1,083
Broadband electro-optic frequency comb generation in a lithium niobate microring resonator
Zhang, M., Buscaino, B., Wang, C., Shams-Ansari, A., Reimer, C., Zhu, R., Kahn, J. M., & Lončar, M. (2019) · Nature · doi:10.1038/s41586-019-1008-7 · Cited by 980
Metadata
- Authors
- Kourogi, M., Nakagawa, K., & Ohtsu, M.
- Venue
- IEEE Journal of Quantum Electronics
- Published
- 1993
- Volume
- 29
- Issue
- 10
- Pages
- 2693-2701
- ISSN
- 0018-9197 (ISSN-L)
- OpenAlex
- W2106832874
- Cited by
- 399
- References
- 3
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wide-span optical frequency comb generator for accurate optical frequency difference measurement. https://app.cochat.ai/papers/10.1109/3.250392
- The paper
- Kourogi, M., Nakagawa, K., & Ohtsu, M. (1993). Wide-span optical frequency comb generator for accurate optical frequency difference measurement. IEEE Journal of Quantum Electronics. https://doi.org/10.1109/3.250392
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.