What size test set gives good error rate estimates?
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We address the problem of determining what size test set guarantees statistically significant results in a character recognition task, as a function of the expected error rate. We provide a statistical analysis showing that if, for example, the expected character error rate is around 1 percent, then, with a test set of at least 10,000 statistically independent handwritten characters (which could be obtained by taking 100 characters from each of 100 different writers), we guarantee, with 95 percent confidence, that: (1) the expected value of the character error rate is not worse than 1.25 E, where E is the empirical character error rate of the best recognizer, calculated on the test set; and (2) a difference of 0.3 E between the error rates of two recognizers is significant. We developed this framework with character recognition applications in mind, but it applies as well to speech recognition and to other pattern recognition problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Some statistical issues in the comparison of speech recognition algorithms
Gillick, L., & Cox, S. J. (2003) · International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1989.266481 · Cited by 636
Bottou, L., & Vapnik, V. (1992) · Neural Computation · doi:10.1162/neco.1992.4.6.888 · Cited by 542 · cited 2×
“Two recognizers have obtained error rates p1 and p2 , pp 12 10 ].”
BackgroundMethodSelf-citation
Cited by
Gene selection for cancer classification using support vector machines
Guyon, I., Weston, J., Barnhill, S., & Vapnik, V. (2002) · Machine Learning · doi:10.1023/a:1012487302797 · Cited by 9,954
Self-citationMCYT baseline corpus: a bimodal biometric database
Ortega-Garcia, J., Fierrez-Aguilar, J., Simon, D., Gonzalez, J., Faundez-Zanuy, M., Espinosa, V., Satue, A., Hernaez, I., Igarza, J.-J., Vivaracho, C., et al. (2003) · IEE Proceedings - Vision, Image, and Signal Processing · doi:10.1049/ip-vis:20031078 · Cited by 757
The UBIRIS.v2: A Database of Visible Wavelength Iris Images Captured On-the-Move and At-a-Distance
Proenca, H., Filipe, S., Santos, R., Oliveira, J., & Alexandre, L. A. (2010) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2009.66 · Cited by 515
Permutation Tests for Classification: Towards Statistical Significance in Image-Based Studies
Golland, P., & Fischl, B. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-45087-0_28 · Cited by 338
Estimating Dataset Size Requirements for Classifying DNA Microarray Data
Mukherjee, S., Tamayo, P., Rogers, S., Rifkin, R., Engle, A., Campbell, C., Golub, T. R., & Mesirov, J. P. (2003) · Journal of Computational Biology · doi:10.1089/106652703321825928 · Cited by 278
On-line signature recognition based on VQ-DTW
Faundez-Zanuy, M. (2007) · Pattern Recognition · doi:10.1016/j.patcog.2006.06.007 · Cited by 260
Trevisan, J., Angelov, P. P., Carmichael, P. L., Scott, A. D., & Martin, F. L. (2012) · The Analyst · doi:10.1039/c2an16300d · Cited by 248
A Comparative Study of Palmprint Recognition Algorithms
Zhang, D., Zuo, W., & Yue, F. (2012) · ACM Computing Surveys · doi:10.1145/2071389.2071391 · Cited by 246
“To discuss the performance difference between palmprint recognition algorithms, we could use several recently developed statistical methods to construct the con.dence intervals for error rates [Guyon et al. 1998; Dass et al. 2006].”
MethodMachine learning in bioinformatics: A brief survey and recommendations for practitioners
Bhaskar, H., Hoyle, D. C., & Singh, S. (2006) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2005.09.002 · Cited by 109
Twelve key challenges in medical machine learning and solutions
Ellis, R. J., Sander, R. M., & Limon, A. (2022) · Intelligence-Based Medicine · doi:10.1016/j.ibmed.2022.100068 · Cited by 61
How Might We Create Better Benchmarks for Speech Recognition?
Aksënova, A., van Esch, D., Flynn, J., & Golik, P. (2021) · Proceedings of the 1st Workshop on Benchmarking: Past, Present and Future · doi:10.18653/v1/2021.bppf-1.4 · Cited by 25
“In terms of size, analyses akin to Guyon et al. (1998) are helpful to ensure that any change is statistically significant; we are not aware of much work along these lines for ASR systems specifically, but it seems like it would be worthwhile to explore this area more.”
Background
Metadata
- Authors
- Guyon, I., Makhoul, J., Schwartz, R., & Vapnik, V.
- Venue
- IEEE Transactions on Pattern Analysis and Machine Intelligence
- Published
- 1998
- Volume
- 20
- Issue
- 1
- Pages
- 52-64
- ISSN
- 0162-8828 (ISSN-L)
- OpenAlex
- W2166312020
- Cited by
- 156
- References
- 2
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.