Control of pneumatic muscle actuators
Abstract
Problems with the control and compliance of pneumatic systems have prevented their widespread use in advanced robotics. However, their compactness, power/weight ratio, and simplicity are factors that could potentially be exploited in sophisticated dextrous manipulator designs. This paper considers the development of a new high power/weight and power/volume braided pneumatic muscle actuator (PMA) having considerable power output potential, combined with controllable motion and inherent compliance to prevent damage to handled objects. Control of these muscles is explored via adaptive pole-placement controllers. Experimental results indicate that accurate position control of 1/spl deg/ is feasible, with power/weight outputs in excess of 1kW/kg at 200kPa.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McKerrow, P. J. (1991) · Medical Entomology and Zoology · Cited by 1,731
Block, H. W., & Kelly, J. P. (1988) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/21/12/001 · Cited by 701
Design of the Utah/M.I.T. Dextrous Hand
Jacobsen, S., Iversen, E., Knutti, D., Johnson, R., & Biggers, K. (1986) · Proceedings. 1986 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1986.1087395 · Cited by 664
The characteristics of the McKibben artificial muscle
Schulte, H. F. J. (1961) · Medical Entomology and Zoology · Cited by 332
Static and dynamic characteristics of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1994.350977 · Cited by 329
Dhillon, B. S. (1991) · Robot Reliability and Safety · doi:10.1007/978-1-4612-3148-6_3 · Cited by 308
Rapid swelling and deswelling of reversible gels of polymeric acids by ionization
Katchalsky, A. (1949) · Experientia · doi:10.1007/bf02172636 · Cited by 208
Rubbertuators and applications for robots
Inoue, K. (1988) · International Symposium on Robotics · Cited by 121
Cited by
Variable impedance actuators: A review
Vanderborght, B., Albu-Schaeffer, A., Bicchi, A., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M., Eiberger, O., Friedl, W., Ganesh, G., et al. (2013) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2013.06.009 · Cited by 1,008
Modeling and control of McKibben artificial muscle robot actuators
(2000) · IEEE Control Systems · doi:10.1109/37.833638 · Cited by 924
Bicchi, A., & Tonietti, G. (2004) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2004.1310939 · Cited by 654
Design of HyQ – a hydraulically and electrically actuated quadruped robot
Semini, C., Tsagarakis, N. G., Guglielmino, E., Focchi, M., Cannella, F., & Caldwell, D. G. (2011) · Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering · doi:10.1177/0959651811402275 · Cited by 630
Lee, C., Kim, M., Kim, Y. J., Hong, N., Ryu, S., Kim, H. J., & Kim, S. (2017) · International Journal of Control, Automation and Systems · doi:10.1007/s12555-016-0462-3 · Cited by 616
Metadata
- Venue
- IEEE Control Systems
- Published
- 1995-02
- Volume
- 15
- Issue
- 1
- Pages
- 40-48
- ISSN
- 1066-033X (ISSN-L)
- 1941-000X
- OpenAlex
- W2070122598
- Cited by
- 468
- References
- 8
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control of pneumatic muscle actuators. https://app.cochat.ai/papers/10.1109/37.341863
- The paper
- Control of pneumatic muscle actuators. (1995). IEEE Control Systems. https://doi.org/10.1109/37.341863
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.