The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Survey of model-based failure detection and isolation in complex plants
Abstract
Techniques to detect and isolate failures in complex technological systems, such as sensor biases, actuator malfunctions, leaks, and equipment deterioration are surveyed. The methods are based on analytical redundancy afforded by a mathematical model of the system. The main components of such techniques are residual generation using the model, signature generation by statistical testing, and signature analysis. Model-structural conditions for failure isolation are introduced together with transformation methods to implement them. Sensitivity and robustness considerations are presented, and a design framework based on model redundancy is proposed.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Process fault detection based on modeling and estimation methods—A survey
Isermann, R. (1984) · Automatica · doi:10.1016/0005-1098(84)90098-0 · Cited by 2,364
A survey of design methods for failure detection in dynamic systems
Willsky, A. S. (1976) · Automatica · doi:10.1016/0005-1098(76)90041-8 · Cited by 2,153
Analytical redundancy and the design of robust failure detection systems
Chow, E., & Willsky, A. S. (1984) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1984.1103593 · Cited by 1,622
A survey of design methods for failure detection in dynamic systems
(1977) · Microelectronics Reliability · doi:10.1016/0026-2714(77)90326-2 · Cited by 1,421
A generalized likelihood ratio approach to the detection and estimation of jumps in linear systems
Willsky, A., & Jones, H. (1976) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1976.1101146 · Cited by 875
Optimally robust redundancy relations for failure detection in uncertain systems
Lou, X.-C., Willsky, A. S., & Verghese, G. C. (1986) · Automatica · doi:10.1016/0005-1098(86)90031-2 · Cited by 386
Detection of Abrupt Changes in Signals and Dynamical Systems
(1985) · Lecture Notes in Control and Information Sciences · doi:10.1007/bfb0006385 · Cited by 330
Fault detection and diagnosis in chemical and petrochemical processes
Himmelblau, D. M. (1978) · Elsevier eBooks · Cited by 283
F-8 DFBW sensor failure identification using analytic redundancy
Deckert, J. C., Desai, M., Deyst, J. J., & Willsky, A. S. (1977) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1977.1101598 · Cited by 239
Instrument fault detection in systems with uncertainties
Watanabe, K., & Himmelblau, D. M. (1982) · International Journal of Systems Science · doi:10.1080/00207728208926337 · Cited by 239
Reconcillation and Rectification of Process Flow and Inventory Data
Mah, R. S., Stanley, G. M., & Downing, D. M. (1976) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260057a030 · Cited by 225
Failure Diagnosis and Performance Monitoring
Pau, L. F. (1986) · IEEE Transactions on Reliability · doi:10.1109/tr.1986.4335511 · Cited by 116
Generating parity relations for detecting and identifying control system component failures
Massoumnia, M.-A., & Velde, W. E. V. (1988) · Journal of Guidance Control and Dynamics · doi:10.2514/3.20270 · Cited by 96
Detection and diagnosis of changes in the eigenstructure of nonstationary multivariable systems
Basseville, M., Albert Benveniste, A., Moustakides, G. V., & Rougée, A. (1987) · Automatica · doi:10.1016/0005-1098(87)90077-x · Cited by 95
Fault diagnosis in nonlinear chemical processes. Part I. Theory
Watanabe, K., & Himmelblau, D. M. (1983) · AIChE Journal · doi:10.1002/aic.690290211 · Cited by 62
Failure diagnosis and performance monitoring
Humble, S. (1982) · Automatica · doi:10.1016/0005-1098(82)90063-2 · Cited by 44
Optimum robust detection of changes in the AR part of a multivariable ARMA process
Rougée, A., Basseville, M., Albert Benveniste, A., & Moustakides, G. V. (1987) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1987.1104500 · Cited by 33
Evaluation of Parity Equations for Gyro Failure Detection and Isolation
Satin, A. L., & Gates, R. L. (1978) · Journal of Guidance and Control · doi:10.2514/3.55738 · Cited by 27
Cited by
Detection of Abrupt Changes: Theory and Application
Riedel, K. S. (1994) · Technometrics · doi:10.1080/00401706.1994.10485821 · Cited by 3,518
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
“other faults, disturbances, and modeling errors, which is called structure residual fault isolation [4].”
BackgroundBibliographical review on reconfigurable fault-tolerant control systems
Zhang, Y., & Jiang, J. (2008) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2008.03.008 · Cited by 2,652
Statistical process monitoring: basics and beyond
Joe Qin, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.800 · Cited by 1,582
Sliding mode observers for fault detection and isolation
Edwards, C., Spurgeon, S. K., & Patton, R. J. (2000) · Automatica · doi:10.1016/s0005-1098(99)00177-6 · Cited by 1,343
Metadata
- Authors
- Gertler, J. J.
- Venue
- IEEE Control Systems Magazine
- Published
- 1988-12
- Volume
- 8
- Issue
- 6
- Pages
- 3-11
- ISSN
- 0272-1708 (ISSN-L)
- OpenAlex
- W2008325098
- Cited by
- 1,114
- References
- 18
- FWCI
- 31.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.