Abstract
A fully 3-D reconstruction algorithm has been developed to reconstruct data from a 16 ring PET camera (a Siemens/CTI 953B) with automatically retractable septa. The tomograph is able to acquire coincidences between any pair of detector rings and septa retraction increases the total system count rate by a factor of 7.8 (including scatter) and 4.7 (scatter subtracted) for a uniform, 20 cm diameter cylinder. The reconstruction algorithm is based on 3-D filtered backprojection, expressed in a form suitable for the multi-angle sinogram data. Sinograms which are not measured due to the truncated cylindrical geometry of the tomograph, but which are required for a spatially invariant response function, are obtained by forward projection. After filtering, the complete set of sinograms is backprojected into a 3-D volume of 128x128x31 voxels using a voxel-driven procedure. The algorithm has been validated with simulation, and tested with both phantom and clinical data from the 953B.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Statistical parametric maps in functional imaging: A general linear approach
Friston, K. J., Holmes, A. P., Worsley, K. J., Poline, J. ‐., Frith, C. D., & Frackowiak, R. S. J. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020402 · Cited by 9,688
Functional and effective connectivity in neuroimaging: a synthesis
Friston, K. J. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020107 · Cited by 2,452
The neural correlates of the verbal component of working memory
Paulesu, E., Frith, C. D., & Frackowiak, R. S. J. (1993) · Nature · doi:10.1038/362342a0 · Cited by 2,230
Castelli, F., Happé, F., Frith, U., & Frith, C. (2000) · NeuroImage · doi:10.1006/nimg.2000.0612 · Cited by 1,290
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Self-citation
Metadata
- Authors
- Townsend, D. W., Geissbuhler, A., Defrise, M., Hoffman, E. J., Spinks, T. J., Bailey, D. L., Gilardi, M.-C., & Jones, T.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1991
- Volume
- 10
- Issue
- 4
- Pages
- 505-512
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2098971073
- Cited by
- 193
- References
- 0
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully three-dimensional reconstruction for a PET camera with retractable septa. https://app.cochat.ai/papers/10.1109/42.108584
- The paper
- Townsend, D. W., Geissbuhler, A., Defrise, M., Hoffman, E. J., Spinks, T. J., Bailey, D. L., Gilardi, M.-C., & Jones, T. (1991). Fully three-dimensional reconstruction for a PET camera with retractable septa. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.108584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.