The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Nonlinear anisotropic filtering of MRI data
Abstract
In contrast to acquisition-based noise reduction methods a postprocess based on anisotropic diffusion is proposed. Extensions of this technique support 3-D and multiecho magnetic resonance imaging (MRI), incorporating higher spatial and spectral dimensions. The procedure overcomes the major drawbacks of conventional filter methods, namely the blurring of object boundaries and the suppression of fine structural details. The simplicity of the filter algorithm permits an efficient implementation, even on small workstations. The efficient noise reduction and sharpening of object boundaries are demonstrated by applying this image processing technique to 2-D and 3-D spin echo and gradient echo MR data. The potential advantages for MRI, diagnosis, and computerized analysis are discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
Adaptive smoothing: a general tool for early vision
Saint-Marc, P., Chen, J.-S., & Medioni, G. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.87339 · Cited by 362
Measuring signal-to-noise ratios in MR imaging.
Kaufman, L., Kramer, D. M., Crooks, L. E., & Ortendahl, D. A. (1989) · Radiology · doi:10.1148/radiology.173.1.2781018 · Cited by 360
MR angiography by multiple thin slab 3D acquisition
Parker, D. L., Yuan, C., & Blatter, D. D. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170215 · Cited by 282
Biased anisotropic diffusion: a unified regularization and diffusion approach to edge detection
Niklas Nordström, K. (1990) · Image and Vision Computing · doi:10.1016/0262-8856(90)80008-h · Cited by 254
Gradient inverse weighted smoothing scheme and the evaluation of its performance
Wang, D. C. C., Vagnucci, A. H., & Li, C. C. (1981) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(81)90077-0 · Cited by 145
Quantitative evaluation of some edge-preserving noise-smoothing techniques
Chin, R. T., & Yeh, C.-L. (1983) · Computer Vision Graphics and Image Processing · doi:10.1016/0734-189x(83)90054-3 · Cited by 112
Cited by
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
A Riemannian Framework for Tensor Computing
Pennec, X., Fillard, P., & Ayache, N. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-005-3222-z · Cited by 1,550
Black, M. J., Sapiro, G., Marimont, D. H., & Heeger, D. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661192 · Cited by 1,295
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Self-citationMorphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Metadata
- Authors
- Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1992-06
- Volume
- 11
- Issue
- 2
- Pages
- 221-232
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2137676365
- Cited by
- 1,149
- References
- 8
- FWCI
- 16.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.