The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Morphometric analysis of white matter lesions in MR images: method and validation
Abstract
The analysis of MR images is evolving from qualitative to quantitative. More and more, the question asked by clinicians is how much and where, rather than a simple statement on the presence or absence of abnormalities. The authors present a study in which the results obtained with a semiautomatic, multispectral segmentation technique are quantitatively compared to manually delineated regions. The core of the semiautomatic image analysis system is a supervised artificial neural network classifier augmented with dedicated preand postprocessing algorithms, including anisotropic noise filtering and a surface-fitting method for the correction of spatial intensity variations. The study was focused on the quantitation of white matter lesions in the human brain. A total of 36 images from six brain volumes was analyzed twice by each of two operators, under supervision of a neuroradiologist. Both the intra- and interrater variability of the methods were studied in terms of the average tissue area detected per slice, the correlation coefficients between area measurements, and a measure of similarity derived from the kappa statistic. The results indicate that, compared to a manual method, the use of the semiautomatic technique not only facilitates the analysis of the images, but also has similar or lower intra- and interrater variabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Measuring nominal scale agreement among many raters.
Fleiss, J. L. (1971) · Psychological Bulletin · doi:10.1037/h0031619 · Cited by 8,733
Pattern Classification and Scene Analysis
Thompson, M., Duda, R. O., & Hart, P. E. (1974) · Leonardo · doi:10.2307/1573081 · Cited by 4,495
ON THE METHODS AND THEORY OF RELIABILITY
BARTKO, J. J., & CARPENTER, W. T. (1976) · The Journal of Nervous and Mental Disease · doi:10.1097/00005053-197611000-00003 · Cited by 1,310
Nonlinear anisotropic filtering of MRI data
Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,149
Scheltens, P., Barkhof, F., Leys, D., Pruvo, J. P., Nauta, J. J. P., Vermersch, P., Steinling, M., & Valk, J. (1993) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(93)90041-v · Cited by 923
Measuring Agreement between Two Judges on the Presence or Absence of a Trait
Fleiss, J. L. (1975) · Biometrics · doi:10.2307/2529549 · Cited by 501
SWIETEN, J. C. V., HOUT, J. H. W. V. D., KETEL, B. A. V., HIJDRA, A., WOKKE, J. H. J., & GIJN, J. V. (1991) · Brain · doi:10.1093/brain/114.2.761 · Cited by 449
Boone, K. B. (1992) · Archives of Neurology · doi:10.1001/archneur.1992.00530290141024 · Cited by 400
Measurement and Reliability: Statistical Thinking Considerations
Bartko, J. J. (1991) · Schizophrenia Bulletin · doi:10.1093/schbul/17.3.483 · Cited by 316
SCHELTENS, P., BARKHOF, F., VALK, J., ALGRA, P. R., HOOP, R. G. V. D., NAUTA, J., & WOLTERS, E. C. (1992) · Brain · doi:10.1093/brain/115.3.735 · Cited by 314
Segmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray Matter
Lim, K. O., & Pfefferbaum, A. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198907000-00006 · Cited by 309
Automatic detection of brain contours in MRI data sets
Brummer, M. E., Mersereau, R. M., Eisner, R. L., & Lewine, R. R. J. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232244 · Cited by 297
Correction of intensity variations in MR images for computer-aided tissue classification
Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251128 · Cited by 291
Self-citationJernigan, T. L. (1990) · Archives of Neurology · doi:10.1001/archneur.1990.00530010035015 · Cited by 257
Neural-network-based segmentation of multi-modal medical images: a comparative and prospective study
Ozkan, M., Dawant, B. M., & Maciunas, R. J. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.241881 · Cited by 211
Self-citationHubert, L. J. (1977) · Psychological Bulletin · doi:10.1037/0033-2909.84.2.289 · Cited by 153
MR signal abnormalities in memory disorder and dementia.
Bowen, B. C., Barker, W., Loewenstein, D., Sheldon, J. J., & Duara, R. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.154.6.2110743 · Cited by 147
Kozachuk, W. E., DeCarli, C., Schapiro, M. B., Wagner, E. E., Rapoport, S. I., & Horwitz, B. (1990) · Archives of Neurology · doi:10.1001/archneur.1990.00530120050009 · Cited by 126
MR signal abnormalities in memory disorder and dementia.
Bowen, B. C., Barker, W., Loewenstein, D., Sheldon, J. J., & Duara, R. (1990) · PubMed Central · Cited by 109
Accuracy and Reproducibility in Volumetric Analysis of Multiple Sclerosis Lesions
Jackson, E. F., Narayana, P. A., Wolinsky, J. S., & Doyle, T. J. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199303000-00007 · Cited by 79
Magnetic resonance findings in patients with early-onset Alzheimer's disease
McDonald, W. M., Ranga, K., Krishnan, R. R., Doraiswamy, P. M., Figiel, G. S., Husain, M. M., Boyko, O. B., & Heyman, A. (1991) · Biological Psychiatry · doi:10.1016/0006-3223(91)90199-v · Cited by 48
Automatic detection of intracranial contours in MR images
Zijdenbos, A. P., Dawant, B. M., & Margolin, R. A. (1994) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)90057-4 · Cited by 37
Self-citationMRI findings of multiple sclerosis with acute transverse myelopathy
Fukazawa, T., Miyasaka, K., Tashiro, K., Hamada, T., Moriwaka, F., Yanagihara, T., & Hamada, K. (1992) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(92)90005-6 · Cited by 26
Periventricular Plaques in Multiple Sclerosis: Irreversible?
Baum, K., Nehrig, C., Schörner, W., & Girke, W. (2008) · European Neurology · doi:10.1159/000116826 · Cited by 10
Magnetic Resonance Imaging Hyperintensities in Alzheimer's Disease
Fazekas, F., Schmidt, R., Offenbacher, H., et al. (1991) · Archives of Neurology · doi:10.1001/archneur.1991.00530170028012 · Cited by 10
Magnetic Resonance Imaging Hyperintensities in Alzheimer's Disease-Reply
Leys, D., Steinling, M., Pruvo, J., Petit, H., Scheltens, P., & Barkhof, F. (1991) · Archives of Neurology · doi:10.1001/archneur.1991.00530170028013 · Cited by 8
Cited by
Chicco, D., & Jurman, G. (2020) · BMC Genomics · doi:10.1186/s12864-019-6413-7 · Cited by 6,143
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Self-citationElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
“The Jaccard Similarity Index (SI) is the measure of the overlap of two or more volumes and is calculated as the ratio of voxel-wise intersection to union of target and reference images [59]:”
BackgroundEvaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Metadata
- Authors
- Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1994
- Volume
- 13
- Issue
- 4
- Pages
- 716-724
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2132513126
- Cited by
- 1,265
- References
- 27
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.