CoChat

Statistics of deformations in histology and application to improved alignment with MRI

Schormann, T., Dabringhaus, A., Zilles, K. · 1995 · IEEE Transactions on Medical Imaging
Cited by 78

The DOI matches its Crossref record.

Abstract

An exact registration of magnetic resonance images (MRI) with histological sections is impeded by local deformations resulting from histological preparation procedures. Therefore, it is desirable to know the probability density function of spatial deformations in order to estimate optimal global least-square transformation parameters from suitable landmarks. For this reason, the statistics of deformations is investigated. It is shown analytically that the frequency of occurrence of the absolute geometrical differences (deformations) are Rayleigh-Bessel distributed for anisotropic histological preparation procedures and Rayleigh distributed in the case of isotropic procedures. The probabilistic analysis is given in conjunction with an iterative optimization technique in order to ensure that the probability density function is within a threshold required for the application to experimental data. The application of the analytical model is investigated with real data. It is shown with this data that the extent of deformations varies with the size of the histological section. An individual threshold can be selected on the basis of a Rayleigh-function restricting local corrections to small parts of the image. Thus, global misalignment in each section can be avoided, resulting in an improved 3-D reconstruction of the volume, i.e., the transitions from one section to the next are more continuous.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.370399

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Schormann, T., Dabringhaus, A., & Zilles, K.
Venue
IEEE Transactions on Medical Imaging
Published
1995-03
Volume
14
Issue
1
Pages
25-35
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2145791464
Cited by
78
References
0
FWCI
3.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.