Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record.

Ultrasonic texture motion analysis: theory and simulation

Meunier, J., Bertrand, M. · 1995 · IEEE Transactions on Medical Imaging

Abstract

A theoretical model was previously developed to evaluate the relationship between the dynamics of ultrasonic speckle and its underlying tissue. The model is divided into an instrumental part represented by the point spread function (in the far field) of the ultrasonic apparatus and a moving tissue component described by a collection of scatterers. By computing the convolution of these terms and then the envelope, one obtains a simulated ultrasonic speckle pattern sequence which shows speckle motions closely linked to the tissue dynamics when small motion amplitudes are involved. Here, a theoretical study of the correlation between various linear transformations of the tissue and the corresponding ultrasonic speckle motions is performed, based on a 2D extension of the envelope cross-correlation analysis of a narrow-band Gaussian noise. In the linear scan case, obviously, tissue translation generates an identical speckle translation. However, tissue/speckle motion correlation decreases with increasing rotation and/or biaxial deformation, lateral deformation (perpendicular to the beam propagation axis) being much less sensitive. With respect to the transducer frequency, the rotation and the axial deformation of the tissue show a better relationship with their respective speckle motion at lower frequencies while lateral deformation correlation is independent of the pulse frequency. With respect to beam (pulse) size parameters, tissue/speckle correlation decreases with rotation when a wide ultrasonic beam is used while the axial deformation correlation decreases with the axial duration of the pulse. This study sets the ground for the development of an ultrasonic strain gauge particularly useful for the assessment of biomechanical soft tissue and fluid flow properties based on speckle tracking.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.387711

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Meunier, J., & Bertrand, M.
Venue
IEEE Transactions on Medical Imaging
Published
1995-06
Volume
14
Issue
2
Pages
293-300
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2130257154
Cited by
191
References
0
FWCI
6.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasonic texture motion analysis: theory and simulation. https://app.cochat.ai/papers/10.1109/42.387711
The paper
Meunier, J., & Bertrand, M. (1995). Ultrasonic texture motion analysis: theory and simulation. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.387711

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).