The DOI matches its Crossref record.
Ultrasonic texture motion analysis: theory and simulation
Abstract
A theoretical model was previously developed to evaluate the relationship between the dynamics of ultrasonic speckle and its underlying tissue. The model is divided into an instrumental part represented by the point spread function (in the far field) of the ultrasonic apparatus and a moving tissue component described by a collection of scatterers. By computing the convolution of these terms and then the envelope, one obtains a simulated ultrasonic speckle pattern sequence which shows speckle motions closely linked to the tissue dynamics when small motion amplitudes are involved. Here, a theoretical study of the correlation between various linear transformations of the tissue and the corresponding ultrasonic speckle motions is performed, based on a 2D extension of the envelope cross-correlation analysis of a narrow-band Gaussian noise. In the linear scan case, obviously, tissue translation generates an identical speckle translation. However, tissue/speckle motion correlation decreases with increasing rotation and/or biaxial deformation, lateral deformation (perpendicular to the beam propagation axis) being much less sensitive. With respect to the transducer frequency, the rotation and the axial deformation of the tissue show a better relationship with their respective speckle motion at lower frequencies while lateral deformation correlation is independent of the pulse frequency. With respect to beam (pulse) size parameters, tissue/speckle correlation decreases with rotation when a wide ultrasonic beam is used while the axial deformation correlation decreases with the axial duration of the pulse. This study sets the ground for the development of an ultrasonic strain gauge particularly useful for the assessment of biomechanical soft tissue and fluid flow properties based on speckle tracking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Measurement of Ventricular Torsion by Two-Dimensional Ultrasound Speckle Tracking Imaging
Notomi, Y., Shiota, T., Popović, Z. B., Weaver, J. A., Oryszak, S. J., Greenberg, N. L., White, R. D., Thomas, J. D., Setser, R. M., White, R. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.082 · Cited by 767
Synthetic aperture imaging for small scale systems
Karaman, M., Li, P.-C., & O'Donnell, M. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.384453 · Cited by 575
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
A theoretical framework for performance characterization of elastography: the strain filter
Varghese, T., & Ophir, J. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.585212 · Cited by 338
Metadata
- Authors
- Meunier, J., & Bertrand, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1995-06
- Volume
- 14
- Issue
- 2
- Pages
- 293-300
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2130257154
- Cited by
- 191
- References
- 0
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonic texture motion analysis: theory and simulation. https://app.cochat.ai/papers/10.1109/42.387711
- The paper
- Meunier, J., & Bertrand, M. (1995). Ultrasonic texture motion analysis: theory and simulation. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.387711
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.