The DOI matches its Crossref record.
Markov random field for tumor detection in digital mammography
Abstract
A technique is proposed for the detection of tumors in digital mammography. Detection is performed in two steps: segmentation and classification. In segmentation, regions of interest are first extracted from the images by adaptive thresholding. A further reliable segmentation is achieved by a modified Markov random field (MRF) model-based method. In classification, the MRF segmented regions are classified into suspicious and normal by a fuzzy binary decision tree based on a series of radiographic, density-related features. A set of normal (50) and abnormal (45) screen/film mammograms were tested. The latter contained 48 biopsy proven, malignant masses of various types and subtlety. The detection accuracy of the algorithm was evaluated by means of a free response receiver operating characteristic curve which shows the relationship between the detection of true positive masses and the number of false positive alarms per image. The results indicated that a 90% sensitivity can be achieved in the detection of different types of masses at the expense of two falsely detected signals per image. The algorithm was notably successful in the detection of minimal cancers manifested by masses </=10 mm in size. For the 16 such cases in the authors' dataset, a 94% sensitivity was observed with 1.5 false alarms per image. An extensive study of the effects of the algorithm's parameters on its sensitivity and specificity was also performed in order to optimize the method for a clinical, observer performance study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Current Methods in Medical Image Segmentation
Pham, D. L., Xu, C., & Prince, J. L. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.315 · Cited by 2,341
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
Computer-aided detection and classification of microcalcifications in mammograms: a survey
Cheng, H. D., Cai, X., Chen, X., Hu, L., & Lou, X. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(03)00192-4 · Cited by 563
Approaches for automated detection and classification of masses in mammograms
Cheng, H. D., Shi, X. J., Min, R., Hu, L. M., Cai, X. P., & Du, H. N. (2006) · Pattern Recognition · doi:10.1016/j.patcog.2005.07.006 · Cited by 538
A review of automatic mass detection and segmentation in mammographic images
Oliver, A., Freixenet, J., Martí, J., Pérez, E., Pont, J., Denton, E. R. E., & Zwiggelaar, R. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.005 · Cited by 398
Metadata
- Authors
- Li, H. D., Kallergi, M., Clarke, L. P., Jain, V. K., & Clark, R. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1995
- Volume
- 14
- Issue
- 3
- Pages
- 565-576
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2164710647
- Cited by
- 246
- References
- 0
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Markov random field for tumor detection in digital mammography. https://app.cochat.ai/papers/10.1109/42.414622
- The paper
- Li, H. D., Kallergi, M., Clarke, L. P., Jain, V. K., & Clark, R. A. (1995). Markov random field for tumor detection in digital mammography. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.414622
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.