The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A multiple active contour model for cardiac boundary detection on echocardiographic sequences
Abstract
Tracing of left-ventricular epicardial and endocardial borders on echocardiographic sequences is essential for quantification of cardiac function. The authors designed a method based on an extension of active contour models to detect both epicardial and endocardial borders on short-axis cardiac sequences spanning the entire cardiac cycle. They validated the results by comparing the computer-generated boundaries to the boundaries manually outlined by four expert observers on 44 clinical data sets. The mean boundary distance between the computer-generated boundaries and the manually outlined boundaries was 2.80 mm (sigma=1.28 mm) for the epicardium and 3.61 (sigma=1.68 mm) for the endocardium. These distances were comparable to interobserver distances, which had a mean of 3.79 mm (sigma=1.53 mm) for epicardial borders and 2.67 mm (sigma=0.88 mm) for endocardial borders. The correlation coefficient between the areas enclosed by the computer-generated boundaries and the average manually outlined boundaries was 0.95 for epicardium and 0.91 for endocardium. The algorithm is fairly insensitive to the choice of the initial curve. Thus, the authors have developed an effective and robust algorithm to extract left-ventricular boundaries from echocardiographic sequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography
Schiller, N. B., Shah, P. M., Crawford, M., DeMaria, A., Devereux, R., Feigenbaum, H., Gutgesell, H., Reichek, N., Sahn, D., Schnittger, I., et al. (1989) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(89)80014-8 · Cited by 8,121
Marr, D., & Hildreth, E. (1980) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1980.0020 · Cited by 6,510
Applied Nonparametric Statistics
Wozniak, P. J., & Daniel, W. W. (1991) · Technometrics · doi:10.2307/1268795 · Cited by 4,987
On active contour models and balloons
Cohen, L. D. (1991) · CVGIP: Image Understanding · doi:10.1016/1049-9660(91)90028-n · Cited by 2,153
Finite-element methods for active contour models and balloons for 2-D and 3-D images
Cohen, L. D., & Cohen, I. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.244675 · Cited by 1,378
Finding Edges and Lines in Images
Canny, J. (1983) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 833
Folland, E. D., Parisi, A. F., Moynihan, P. F., Jones, D. R., Feldman, C. L., & Tow, D. E. (1979) · Circulation · doi:10.1161/01.cir.60.4.760 · Cited by 726
Cited by
Deformable models in medical image analysis: a survey
McInerney, T., & Terzopoulos, D. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80007-7 · Cited by 1,913
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
A methodology for evaluation of boundary detection algorithms on medical images
Chalana, V., & Kim, Y. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640755 · Cited by 542
Self-citationSpeckle reduction and contrast enhancement of echocardiograms via multiscale nonlinear processing
Zong, X., Laine, A. F., & Geiser, E. A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730398 · Cited by 337
Deformable models in medical image analysis
McInerney, T., & Terzopoulos, D. (1996) · Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis · doi:10.1109/mmbia.1996.534069 · Cited by 329
Metadata
- Authors
- Chalana, V., Linker, D. T., Haynor, D. R., & Kim, Y.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1996-06
- Volume
- 15
- Issue
- 3
- Pages
- 290-298
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2097222278
- Cited by
- 305
- References
- 18
- FWCI
- 19.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multiple active contour model for cardiac boundary detection on echocardiographic sequences. https://app.cochat.ai/papers/10.1109/42.500138
- The paper
- Chalana, V., Linker, D. T., Haynor, D. R., & Kim, Y. (1996). A multiple active contour model for cardiac boundary detection on echocardiographic sequences. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.500138
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.