Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record.

Adaptive speckle reduction filter for log-compressed B-scan images

Dutt, V., Greenleaf, J.F.·1996·IEEE Transactions on Medical Imaging

Abstract

A good statistical model of speckle formation is useful for designing a good adaptive filter for speckle reduction In ultrasound B-scan images. Previously, statistical models have been used, but they failed to account for the log compression of the echo envelope employed by clinical ultrasound systems. Log-compression helps in reducing the dynamic range of the B-scan Images for display on a monitor as well as enhancing weak backscatters. In this article, statistics of log-compressed echo images, using the K-distribution statistical model for the echo envelope, are used to derive a parameter that can be used to quantify the extent of speckle formation. This speckle quantification can be used with an unsharp masking filter to adaptively reduce speckle. The effectiveness of the filter is demonstrated on images of contrast detail phantoms and on in-vivo abdominal images obtained by a clinical ultrasound system with log-compression.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.544498

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
Dutt, V., & Greenleaf, J. F.
Venue
IEEE Transactions on Medical Imaging
Published
1996-12
Volume
15
Issue
6
Pages
802-813
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2115310626
Cited by
199
References
0
FWCI
1.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive speckle reduction filter for log-compressed B-scan images. https://app.cochat.ai/papers/10.1109/42.544498
The paper
Dutt, V., & Greenleaf, J. F. (1996). Adaptive speckle reduction filter for log-compressed B-scan images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.544498

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.