CoChat

A methodology for specifying PET VOIs using multimodality techniques

Klein, G.J., Teng, X., Jagust, W.J., Eberling, J.L., Acharya, A., Reutter, B.W., Huesman, R.H. · 1997 · IEEE Transactions on Medical Imaging
Cited by 32

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Volume-of-interest (VOI) extraction for radionuclide and anatomical measurements requires correct identification and delineation of the anatomical feature being studied. We have developed a toolset for specifying three-dimensional (3-D) VOI's on a multislice positron emission tomography (PET) dataset. The software is particularly suited for specifying cerebral cortex VOI's which represent a particular gyrus or deep brain structure. A registered 3-D magnetic resonance image (MRI) dataset is used to provide high-resolution anatomical information, both as oblique two-dimensional (2-D) sections and as volume renderings of a segmented cortical surface. VOI's are specified indirectly in two dimensions by drawing a stack of 2-D regions on the MRI data. The regions are tiled together to form closed triangular mesh surface models, which are subsequently transformed into the observation space of the PET scanner. Quantification by this method allows calculation of radionuclide activity in the VOI's, as well as their statistical uncertainties and correlations. The methodology for this type of analysis and validation results are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.611350

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 32

Metadata

Authors
Klein, G. J., Teng, X., Jagust, W. J., Eberling, J. L., Acharya, A., Reutter, B. W., & Huesman, R. H.
Venue
IEEE Transactions on Medical Imaging
Published
1997
Volume
16
Issue
4
Pages
405-415
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2124309348
Cited by
32
References
1
FWCI
2.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A methodology for specifying PET VOIs using multimodality techniques. https://app.cochat.ai/papers/10.1109/42.611350
The paper
Klein, G. J., Teng, X., Jagust, W. J., Eberling, J. L., Acharya, A., Reutter, B. W., & Huesman, R. H. (1997). A methodology for specifying PET VOIs using multimodality techniques. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.611350

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.