The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Measures of acutance and shape for classification of breast tumors
Abstract
Most benign breast tumors possess well-defined, sharp boundaries that delineate them from surrounding tissues, as opposed to malignant tumors. Computer techniques proposed to date for tumor analysis have concentrated on shape factors of tumor regions and texture measures. While shape measures based on contours of tumor regions can indicate differences in shape complexities between circumscribed and spiculated tumors, they are not designed to characterize the density variations across the boundary of a tumor. In this paper we propose a region-based measure of image edge profile acutance which characterizes the transition in density of a region of interest (ROI) along normals to the ROI at every boundary pixel. We investigate the potential of acutance in quantifying the sharpness of the boundaries of tumors, and propose its application to discriminate between benign and malignant mammographic tumors. In addition, we study the complementary use of various shape factors based upon the shape of the ROI, such as compactness, Fourier descriptors, moments, and chord-length statistics to distinguish between circumscribed and spiculated tumors. Thirty-nine images from the Mammographic Image Analysis Society (MIAS) database and an additional set of 15 local cases were selected for this study. The cases included 16 circumscribed benign, seven circumscribed malignant, 12 spiculated benign, and 19 spiculated malignant lesions. All diagnoses were proven by pathologic examinations of resected tissue. The contours of the lesions were first marked by an expert radiologist using X-Paint and X-Windows on a SUN-SPARCstation 2 Workstation. For computation of acutance, the ROI boundaries were iteratively approximated using a split/merge and end-point adjustment technique to obtain the best-fitting polygonal approximation. The jackknife method using the Mahalanobis distance measure in the BMDP (Biomedical Programs) package was used for classification of the lesions using acutance and the shape factors as features in various combinations. Acutance alone resulted in a benign/malignant classification accuracy of 95% the MIAS cases. Compactness alone gave a circumscribed/spiculated classification rate of 92.3% with the MIAS cases. Acutance in combination with a moment-based shape measure and a Fourier descriptor-based measure gave four-group classification rate of 95% with the MIAS cases. The results indicate the importance of including lesion edge definition with shape information for classification of tumors, and that the proposed measure of acutance fills this need.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Visual pattern recognition by moment invariants
Hu, M.-K. (1962) · IEEE Transactions on Information Theory · doi:10.1109/tit.1962.1057692 · Cited by 7,546
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-21955-6 · Cited by 4,596
Pattern Classification and Scene Analysis.
Clarke, M. R. B., Duda, R. O., & Hart, P. E. (1974) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344977 · Cited by 3,222
BMPD statistical software manual
Dixon, W. (1988) · University of California Press eBooks · Cited by 2,536
Gupta, R. P. (1991) · Remote Sensing Geology · doi:10.1007/978-3-662-12914-2_12 · Cited by 1,425
The Mammographic Image Analysis Society digital mammogram database
John Suckling, A., Parker, J., Astley, S., Hutt, I., Boggis, C. R. M., Ricketts, I. W., Stamatakis, E. A., Cerneaz, N., Kok, S., Taylor, P., et al. (1994) · Cited by 1,155
Shape Discrimination Using Fourier Descriptors
Persoon, E., & Fu, K.-S. (1977) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1977.4309681 · Cited by 1,073
Report of the International Workshop on Screening for Breast Cancer
Fletcher, S. W., Black, W., Harris, R., Rimer, B. K., & Shapiro, S. (1993) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/85.20.1644 · Cited by 792
(1985) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(85)80079-7 · Cited by 423
Cited by
Large scale deep learning for computer aided detection of mammographic lesions
Kooi, T., Litjens, G., van Ginneken, B., Gubern-Mérida, A., Sánchez, C. I., Mann, R., den Heeten, A., & Karssemeijer, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.07.007 · Cited by 965
Approaches for automated detection and classification of masses in mammograms
Cheng, H. D., Shi, X. J., Min, R., Hu, L. M., Cai, X. P., & Du, H. N. (2006) · Pattern Recognition · doi:10.1016/j.patcog.2005.07.006 · Cited by 538
A review of automatic mass detection and segmentation in mammographic images
Oliver, A., Freixenet, J., Martí, J., Pérez, E., Pont, J., Denton, E. R. E., & Zwiggelaar, R. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.005 · Cited by 398
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
A review of computer-aided diagnosis of breast cancer: Toward the detection of subtle signs
Rangayyan, R. M., Ayres, F. J., & Leo Desautels, J. E. (2007) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2006.09.003 · Cited by 337
Self-citation
Metadata
- Authors
- Rangayyan, R. M., El-Faramawy, N. M., Desautels, J. E. L., & Alim, O. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997
- Volume
- 16
- Issue
- 6
- Pages
- 799-810
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2144647583
- Cited by
- 318
- References
- 20
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measures of acutance and shape for classification of breast tumors. https://app.cochat.ai/papers/10.1109/42.650876
- The paper
- Rangayyan, R. M., El-Faramawy, N. M., Desautels, J. E. L., & Alim, O. A. (1997). Measures of acutance and shape for classification of breast tumors. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.650876
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.