Performance evaluation of the PC-2048: a new 15-slice encoded-crystal PET scanner for neurological studies
The DOI matches its Crossref record.
Abstract
Initial experience is reported with the Scanditronix PC 2048-15B, a 15-slice positron emission tomography (PET) system using multicrystal/multiphoto-multiplier modules to obtain high spatial resolution. Random and scattered events are reduced using an orbiting (68)Ge rod source for transmission scans by only accepting coincidence lines which intersect the instantaneous position of the source. Scatter correction of the emission data is removed with a deconvolution kernel, random and dead-time correction by the use of observed singles rates. The peak count rates are 11.7/20.0 Kcps for the direct cross slices at concentrations of 4.5/5.1 muCi/cc. respectively. Over the radial range 0-9 cm from the ring center, radial transverse resolution is 4.6-6.4 mm, aid tangential transverse resolution is 4.6-5.1 mm using a Hanning filter. Over the same range, axial resolution varies from 6.1-6.2 mm in direct slices and from 5.4-7.1 mm in cross slices. This near-isotropic resolution allows collection of image volume data with no preferred direction for signal averaging errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A three-dimensional statistical analysis for CBF activation studies in human brain
Worsley, K. J., Evans, A. C., Marrett, S., & Neelin, P. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.127 · Cited by 2,036
Self-citationLateralization of phonetic and pitch discrimination in speech processing
Zatorre, R. J., Evans, A. C., Meyer, E., & Gjedde, A. (1992) · Science · doi:10.1126/science.256.5058.846 · Cited by 1,507
Self-citationMultiple Representations of Pain in Human Cerebral Cortex
Talbot, J. D., Marrett, S., Evans, A. C., Meyer, E., Bushnell, M. C., & Duncan, G. H. (1991) · Science · doi:10.1126/science.2003220 · Cited by 971
Self-citationDifferences between males and females in rates of serotonin synthesis in human brain
Nishizawa, S., Benkelfat, C., Young, S. N., Leyton, M., Mzengeza, S., de Montigny, C., Blier, P., & Diksic, M. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.10.5308 · Cited by 900
Distributed processing of pain and vibration by the human brain
Coghill, R., Talbot, J., Evans, A., Meyer, E., Gjedde, A., Bushnell, M., & Duncan, G. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-07-04095.1994 · Cited by 808
Self-citation
Metadata
- Authors
- Evans, A. C., Thompson, C. J., Marrett, S., Meyer, E., & Mazza, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1991-03
- Volume
- 10
- Issue
- 1
- Pages
- 90-98
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2134187299
- Cited by
- 98
- References
- 0
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance evaluation of the PC-2048: a new 15-slice encoded-crystal PET scanner for neurological studies. https://app.cochat.ai/papers/10.1109/42.75615
- The paper
- Evans, A. C., Thompson, C. J., Marrett, S., Meyer, E., & Mazza, M. (1991). Performance evaluation of the PC-2048: a new 15-slice encoded-crystal PET scanner for neurological studies. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.75615
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.